4.6 Mounting the rod lock
CAUTION
Damage to the rod lock due to incorrect actuation / overload!
•
The rod lock may only be triggered and unlocked when the
product has been shut down.
•
See the data on static holding force in the catalog. The forces
occurring in a clamped condition must not exceed the holding
force.
•
In the event of a dynamic load or overload (e.g. drop in
pressure during movement), the clamping cartridge must be
checked and replaced if necessary.
WARNING
The rod lock is not a safety component for personal protection
in the sense of the Machine Directive.
Assembly of
ASP rod lock
Ø
Disassemble face plate I (C) and cover plate I (B)
Ø
Install the completely installed rod lock (A).
Ø
Cover plate (B) is no longer required.
Ø
Install face plate I (C).
Ø
Removing screw from air connection (1)
✔
Clamping is active and must be released by the appropriate air
pressure.