4.3 Adjust stroke, sensors and damping
4.3.1 End positions - Sets CLM 08
The following components are available for stroke limiting, shock
absorption and monitoring of the end positions:
• End stop without sensor system LMAS 08-KT
• End stop with sensor system NIA 50-KT
wrench
stroke
locknut
clamping insert
Linear module end positions – Set CLM 08
Size
Min. distance Y [mm]
CLM 08
1.0
CAUTION
Material damage due to erroneous settings!
•
Do not fall below minimum distance Y.
•
The end stop is the respective shock absorber on both sides;
the inside of the product must not hit the end stop.
Stroke adjustment/
sensor adjustment
Set end position "linear module extended":
Ø
Loosen the attachment screw.
Ø
Set the end stop to the desired stroke with the wrench supplied.
IMPORTANT! Do not fall below minimum distance Y.
✓
The optionally integrated sensor moves with the machine
and does not need to be readjusted.
Ø
Tighten the attachment screw.
✓
Maximum permissible tightening torque: 0.6 Nm
Set analog end position "Linear module retracted".