background image

   
The display shows: 

Energy-saving-mode.

11. With the buttons 

+

 and 

 you can switch the energy-saving-mode on/off.

12. Press button 1.

 

      The display shows: 

Overall counter

.

      Here you can see the number of all pressing activations.
13. Press button 1.

      The display shows: 

Hours of work.

      Here you can see the number of hours the press has worked.
14. press button 1.

    

     The display shows: 

Diagnostic function

.

     Here you can check the electric circuits:  - temperature fuse

- thermo couple
- power relay

15. To end the programming mode, press button 1.

3.2   Resetting of the electronic devices      

                                                                                                      

Attention!

You only should reset the heat press after getting in contact with the producer.

To reset the heat press, press button 1 and 2 at the same time. Button 1 should be pressed 1 
second earlier. Hold the buttons 20 sec.
 Confirm the action with button 2 or cancel it with button 3. If you press the button YES the 
Temperature will change to the original setting.

3.3   Error reports  

                                                                                                      

The electronic devices of the Big-O-Lite pneu control the main functions of the press. 

Here is a list of possible messages:

ERR.1 – No connection of the electronic devices to the temperature sensor. (

Temperature sensor defect/

 cable not connected)

ERR.2 – Connection of electronic devices and temperature sensor bypassed. (

Temperature sensor defect/

)

ERR.3 – Resistor of temperature sensor too low. The temperature range of the electronic devices is deceeded.
ERR.4 – Resistor of temperature sensor too high. The temperature range of the electronic devices exceeded.
ERR.5 – No temperature rise within 3 minutes even if heating element is switched on. (

Temperature fuse is defect

)

ERR.6 – No reduction of the temperature within 3 minutes even if heating element is turned off. 

(Power relay CRYDOM is defect)

ERR.7 – Temperature too high, over 230°C  

(Power relay CRYDOM is defect)

ERR.3 and ERR.4 can occur if the electronic devices are not programmed properly.

Version 16.01                                                                          9 /  18

Summary of Contents for Big-O-Lite pneu plus

Page 1: ...Instruction manual Version 16 01 Heat press Big O Lite pneu plus Version 16 01 1 18...

Page 2: ...devices 07 3 2 Resetting of the electronic devieces 09 3 3 Error reports 09 3 4 ECO mode 10 3 5 Prepressing 10 3 6 Application range and sample adjustments of the heat press 10 3 7 Pressure settings 1...

Page 3: ...drawer 14 Handle to pull out the base plate 15 Contact pressure adjustment 16 Compressed air connection 17 Air filter with water separator 18 Extractable handles 19 Main switch 1 3 Technical data Dime...

Page 4: ...to be replaced The instruction for replacing the main fuse can be found in chapter 4 3 Thermal fuse The thermal fuse is placed directly on the heating plate and it stops the power supply if the temper...

Page 5: ...press has to be wide enough to let nothing disturb the user at work Using the press with certain materials may create a strong smell That s why the user should evaluate the need for a ventilation sys...

Page 6: ...o a voltage of 230VAC 50Hz The press is equipped with a plug Make sure that the power outlet is in the right condition and that the grounding is connected to the power outlet Caution please do not con...

Page 7: ...3 Working with the heat press 3 1 Programming of electronic devices Version 16 01 7 18...

Page 8: ...er switching on the counter it counts the number of pressing activities a To end the programming of the electronic devices press button 1 b to get to the advanced programming menu press button 1 for 3...

Page 9: ...press the button YES the Temperature will change to the original setting 3 3 Error reports The electronic devices of the Big O Lite pneu control the main functions of the press Here is a list of poss...

Page 10: ...All information is supplied without liability please run your own testing before production 3 7 Pressure settings With this press you can change the pressure setting After every change of the pressure...

Page 11: ...otos 4 6 and the heating plate must be carefully put on soft surface so as not to damage the teflon Then take the new heating plate and tighten it with the wrench Connect the heating plate with the pr...

Page 12: ...compressor Oil in the system may be damage the press 4 2 Monthly Maintenance Before beginning maintenance work control if the press is turned off and cold Disconnect the press from electricity Some m...

Page 13: ...e the electronic devices turn off the press and pull the plug Unscrew the cover of the press as in chapter 4 4 Pull out the green plug photo 1 Pull out the electronics keyboard photo 2 Remove the stop...

Page 14: ...the mat lays exactly over each other 6 Let the glue dry for 24hours 7 Take of the heating plate and cut off the overlaying edge of the silicon mat 4 8 Replacing the thermal fuse The replacing may only...

Page 15: ...couple is too low Exchange the thermo couple The displayshows Err 4 Resistance of the thermo couple is too high The displayshows Err 6 Power relayCRYDOM is defect Replace power relayCRYDOM The displa...

Page 16: ...4 10 Connection diagram Version 16 01 16 18...

Page 17: ...4 11 Controlling of the pneumatics Version 16 01 17 18...

Page 18: ...K hereby declares that the following machine Heat press serial number is compliant with the specifications of the following EC directives Machinery 2006 42 EC Low Voltage 2014 35 EU EMC 2014 30 EU use...

Reviews: