Place the press on the closet and connect it using screws. It will prevent the press from sliding.
(photos 8-9)
2.3 Connection of the press to compressed air
The Airpress is a pneumatic press, which has to be connected to compressed air. The maximum pressure inside the press must not
exceed 6 bar. The air has to be dry and clear of oil. If required you may employ additional filter and drier. The port for the compressed air
at the press is equipped with a quick connect.
After working with the press disconnect the compressed air. So the container with the condensed water will empty automatically. If you
compressed air system isn't equipped with an air drier, you need to check the container every 4 hour and empty it. Therefore press the
knob A
(photo 1)
upwards.
To remove the container, disconnect the compressed air first. Push the container up and turn it to the left, now you may remove it. If there
is oil in the container you need to switch off the press at once and repair the compressor. Oil in the system may be damage the press.
2.4
Power supply
The Big-O-Lite has to be connected to a voltage of 230VAC/ 50Hz. The press is equipped with a plug. Make sure that the power outlet is
in the right condition and that the grounding is connected to the power outlet.
Caution:
please do not connect this press to any other outlet (socket) than those equipped with
ground-fault protection
ELCB (
e
arth
l
eakage
c
ircuit breaker).
2.5
Initiation of the heat press
The press should only be used by trained personal after notice of this manual. Before the initial start up make sure that the power outlet
is in the right condition and that the grounding is connected to the power outlet.
While powering up the press, the movable part has to be in the upper position, which means that the press has to be open. The press
also has to be open while heating up.
The press can be turned on with the big dip-switch
(photo 1).
The press heats up to the adjusted temperature.
Start the press with both green buttons START
(photo 2).
Connect the press to the compressed air, the pressure must not exceed 6 bar.
If your are not using the press, please disconnect the compressed air.
After finishing the work with the press the switch has to be turned off and the plug has to be pulled out.
If you want to be off the press before the end of press time, press the emergency stop switch
(photo 3).
Version 16.01 6 / 18
Summary of Contents for Big-O-Lite pneu plus
Page 1: ...Instruction manual Version 16 01 Heat press Big O Lite pneu plus Version 16 01 1 18...
Page 7: ...3 Working with the heat press 3 1 Programming of electronic devices Version 16 01 7 18...
Page 16: ...4 10 Connection diagram Version 16 01 16 18...
Page 17: ...4 11 Controlling of the pneumatics Version 16 01 17 18...