39
Incorrect grounding conductor /connector installation may result in electric shock risk.
Whenever connector or cable repair or replacement is needed, do not plug conductor/connector to any feeding
conductors. The grounding conductor - one with green covering, with or without yellow stripes - is suitable
exclusively for grounding. If there is any doubt regarding this information, or about whether the product is ade-
quately grounded, consult an expert electrician (one who is acquainted with electrical installation standards).
ATTENTION
TABLE 8.1- GUIDE FOR WIRES AND FUSES
MOTOR
POWER (CV)
LOCAL VOLTA-
GE (V)
MOTOR
CURRENT (A)
WIRE
(mm²)
MAX. DISTANCE (m)
FUSE F1
(A)
VOLTAGE DROP (%)
2
SINGLE-PHASE MOTORS
1/2
127
7,60
1,5
13
25
220
3,80
1,5
50
16
THREE-PHASE MOTORS
1/2
220
2,25
1,5
86
6
380
1,30
1,5
254
4
LEGEND
Q
SWITCH SECCIONADORA
DR
RESIDUAL DIFFERENTIAL SWITCH
KS
RELAY SAFETY
K1/K2
CONTACTOR TRIPOLAR
FT1
OVERLOAD RELAY
M 1~
ELECTRIC MOTOR SINGLE-PHASE
M 3~
ELECTRIC MOTOR THREE-PHASE
T1
CONVERTER
B1
EMERGENCY BUTTON
S1/S2
BUTTONS ON/OFF
F1,2
FUSE
R
RESET BUTTON
RESPONSIBILITY OF THE CUSTOMER
GROUND
SUPPLY VOLTAGE
2
1
Q
4
3
4
3
2
1
DR
FT1
1
3
5
2
4
6
K1
5
6
K1
3
4
K1
1
2
2
1
M
1
2
1
K2
4
3
K2
6
5
K2
F1
F2
B1
11
12
21
22
S11
S21
S12
S22
KS
A1
A2
24Vac
K1
A1
A2
A2
A1
K2
S2
FT1
95
96
S1
K1
K2
R
14
13
KS
T1
F
F/N
FIGURE 8.1- SINGLE-PHASE ELECTRICAL CONNECTION SCHEME