CPCI H.110 Backplane 23006 - 601
User Manual (Rev000)
Schroff GmbH, Okt. 2005; Document#: 73972-105, Rev.: 000
www.schroff.de
Page 2 of 2
Utility / SENSE Connector pinout
FAL#: Signal driven by intelligent PSU's,
at least one output has failed (is out
of range)
DEG#: Signal driven by intelligent PSU's,
PSU indicates that the supply is
beginning to derate its power output
A B
6
5
4
3
2
1
A
B
6
nc
nc.
5
nc
-12V
4
+12V
3,3V
3
GND
+5V
2
FAL#
DEG#
1
nc
PRST#
Sense:
Voltage rails +5V; 3,3V; +12V
and GND of these connectors used for
sense purposes. They should be
connected to the backplane.
Some Power Supplies need at least a
connection to GND, otherwise the
outputs overrun
Cable assy (350mm): Schroff 23204 - 115
23006-601, CPCI Backplane with H.110 bus, 8 Slot (rear view)
8
7
6
5
4
3
2
1
SELVbat
Utility
Vbat, VRG
IPMB0
IPBM1
V I/O Bridge
(set to +5V by
default)
Connectors
for optional
termination
adapter
Telephony Rear I/O (P5); Slots 2 to 8
Tel. Voltage Supply Bus (P4); Slots 2 to 8
Telephony H.110 Bus (P4); Slots 2 to 8
161,56 mm
262,05 mm
nGA[0] to
nGA[7]