background image

CPCI H.110 Backplane 23006 - 601

                                               

User Manual  (Rev000)

Schroff GmbH, Okt. 2005; Document#: 73972-105, Rev.: 000
www.schroff.de

Page 2 of 2

Utility / SENSE Connector pinout

FAL#: Signal driven by intelligent PSU's,

at least one output has failed (is out
of range)

DEG#: Signal driven by intelligent PSU's,

PSU indicates that the supply is
beginning to derate its power output

A    B

6
5
4
3
2
1

A

B

6

nc

nc.

5

nc

-12V

4

+12V

3,3V

3

GND

+5V

2

FAL#

DEG#

1

nc

PRST#

Sense: 

Voltage rails +5V; 3,3V; +12V

and GND of these connectors used for
sense purposes. They should be
connected to the backplane.
Some Power Supplies need at least a
connection to GND, otherwise the
outputs overrun

Cable assy (350mm): Schroff 23204 - 115

23006-601, CPCI Backplane with H.110 bus, 8 Slot (rear view)

8

7

6

5

4

3

2

1

SELVbat

Utility

Vbat, VRG

IPMB0

IPBM1

V I/O Bridge

(set to +5V by

default)

Connectors

for optional
termination

adapter

Telephony Rear I/O (P5); Slots 2 to 8

Tel. Voltage Supply Bus (P4); Slots 2 to 8

Telephony H.110 Bus (P4); Slots 2 to 8

161,56 mm

262,05 mm

nGA[0] to
nGA[7]