VXS/VME64x Tower System
Technical Data
10836-060
www.schroff.biz
16
R1.1, May 04, 2009
5 Technical Data
Table 2: Technical Data
Dimensions
Height
448.7 mm
Width
496.25 mm
Depth
300 mm
Weight
14 kg
Power supply
Input voltage
100 VAC to 240 VAC
Mains frequency
50 / 60 Hz
Power consumption)
up to 250 W
Cooling
4 x 24 VDC Fans
Each 125 m³/h (75 cfm)
Ambient Temperature
Operating
0 °C to +45 °C
Storage
-40 °C to +85 °C
Humidity
permissable Humidity
30 % to 80 %, non condensing
EMC, the system meets the
requirements for:
Emitted Interference
EN 55022
Interference Resistance
EN 55024
Safety
Test voltage according to EN 60950
Input - Output:
Input- PE:
Output - PE:
Output - Output:
4,3 kVDC
2,2 kVDC
0,7 kVDC
0,7 kVDC
Shock and Vibration:
EN 60068-2-6 and EN 60068-2-27
Electromagnetic Shielding
Shielding attenuation
typ. 40 dB at 1 GHz if shielded front
panels are used.