2.4.1 Grounding
2.4.2 Power Supply
Figure 3: Power Supply
Table 1: Data AC Power Supply
e
Caution!
The unit is designed in accordance with protection class 1! It must therefore be
operated with protective earth/GND connection. Use only a three conductor
AC power cable with a protective earth conductor that meets the IEC safety
standards!
10007814
Input voltage nominal
100 - 240 VAC
Mains Frequency
50 / 60 Hz
Output (max.)
250 W
Output voltages
3.3
5.0
12.0
-12.0
V
V
V
V
-
-
-
-
40
40
5.5
2
A
A
A
A
Ripple
< 1 %
Dynamic response
< 1 % or 60 mV
Recovery time to within 1%
< 300 µsec
Overvoltage protection
for all voltages
120 – 130 % U > 5 V
Overcurrent protection
105 – 130 % of rated output current
Hold-up time
>= 20 ms