background image

VXS/VME64x Tower System

Safety

10836-060

www.schroff.biz

1

R1.1, May 04, 2009

1  Safety

1.1  Intended Application

The VXS/VME64x Tower System, described in this manual, is intended as a 
platform for a microcomputer system based on the VXS/VME bus system (VME 
(VITA 1-1994), VME64x (VITA 1.1-1997), VXS (VITA 41.0/1/10/11)).
The VXS/VME64x Tower System is designed for protection class IP 20 and can 
be used only in the resp. environments. 

VXS/VME64x Tower Systems are not end-products, so there is no valid 
approval for this unit. In order to enable stand-alone functionality, additional 
elements are required. An operational system is achieved only by way of 
appropriate VXS or VME64x boards.
The completion and final testing of the units have been carried out, or at least 
supervised, by qualified technicians. These instructions are directed exclusively 
to these qualified technicians i.e.engineers, trained and qualified electricians 
etc. 

Make sure that:

the assembled unit complies with the safety regulations currently applicable 
in the country it is going to be used.

the overall unit complies with all other regulations and specifications at the 
place and country of use, e.g. interference limits, approval by the telecom-
munications authorities.

Summary of Contents for 10836-060

Page 1: ...VXS VME64x Tower System User s Manual Product No 10836 060 May 04 2009 Doc No 63972 161_R1 1...

Page 2: ...ISO 9001 2000 The company cannot accept any liability for errors or misprints The company reserves the right to amendments of technical specifications due to further development and improvement of pro...

Page 3: ...al Overview 5 2 2 Tower System 6 2 3 VXS VME64x Backplane 6 2 4 Power Supply 7 2 4 1 Grounding 8 2 4 2 Power Supply 8 2 4 3 Wiring Diagram 9 2 5 Thermals 10 2 6 Fan Control Module FCM 11 2 7 Display M...

Page 4: ...VXS VME64x Tower System 10836 060 www schroff biz II R1 1 May 04 2009...

Page 5: ...In order to enable stand alone functionality additional elements are required An operational system is achieved only by way of appropriate VXS or VME64x boards The completion and final testing of the...

Page 6: ...ates that there are dangerous voltages inside the Shelf Caution This is the user caution symbol It indicates a condition where damage of the equipment or injury of the service personnel could occur To...

Page 7: ...ME64x Backplanes Order no 73972 103 Short Form User Manual VXS VME64x Backplane 23001 701 Order no 73972 125 User Manual Fan Control Module FCM Order no 73972 083 User Manual Power Supply Order no 739...

Page 8: ...U 80 mm deep A Backplane with 4 slots VME64x VITA 1 1 1997 3 VXS slots VITA 41 0 1 10 11 and 2 P47 connectors for plug in power supplies A 19 plug in power supply with wide range input Speed controll...

Page 9: ...1 Mechanical Overview 10007848 1 Front panel 5 U 8 HP 8 Air Filter 2 Display Module 9 Front panel perforated 3 AC Switch 10 Rear Fans 4 19 Power Supply 11 AC Connector IEC320 C14 with filter and fuse...

Page 10: ...e installation of 7 Rear I O Boards 6 U 4 HP 80 mm deep The lower guide rails are fitted with ESD clips Two slots for 19 plug in power supplies are located right to the card cage 2 3 VXS VME64x Backpl...

Page 11: ...2 Fuses Hazardous voltage Parts of the power supply may be exposed with hazardous voltage Always remove mains line connector before carry out any assembly work Caution Your system has not been provide...

Page 12: ...tive earth GND connection Use only a three conductor AC power cable with a protective earth conductor that meets the IEC safety standards 10007814 Input voltage nominal 100 240 VAC Mains Frequency 50...

Page 13: ...Anode Fan Fail Anode Tmp Fail Anode GND Cath com 12 V Cath 1 2 X50 12 V 3 3 V 12 V 5 V GND X1 Fan Control Module X100 Backplane Power Supply 1 DISPLAY 10 5 7 11 1 12 3 9 Tacho Signal Fan Power Fan Pow...

Page 14: ...rns 90 upward As the air passes across the hot components on the Front Boards heat is carried away by forced convection The air exits the Subrack at the top is drawn into the upper plenum turns 90 and...

Page 15: ...fail LED and a digital output are activated Since the fan speed is temperature controlled by the FCM the fans rotate with the lowest speed possible Lower speeds reduce acoustic noise and increase the...

Page 16: ...1 1 Ensuring Proper Airflow Maintain ambient airflow to ensure normal operation If the airflow is blocked or restricted or if the intake air is too warm an over temperature condition can occur Ensure...

Page 17: ...en the rear panel mounting screws Power on the system and determine the actual current consumption Replace the mains fuses suitable to the actual current Warning Voltages over 60 VDC can be present in...

Page 18: ...signated as a device A CE symbol is therefore not required However the systems comply with all requirements Each individual component complies to the EMC standard 89 336 EWG and to the low frequency s...

Page 19: ...r max 7 Boards 6 U 80 mm deep Guide rails incl ESD Clips 1 AC mains line module with IEC 320 C14 connector mains fuses and line filter 1 3 U 8 HP plug in power supply 250 W with wide range input 100 V...

Page 20: ...Each 125 m h 75 cfm Ambient Temperature Operating 0 C to 45 C Storage 40 C to 85 C Humidity permissable Humidity 30 to 80 non condensing EMC the system meets the requirements for Emitted Interference...

Page 21: ...VXS VME64x Tower System Dimensions 10836 060 www schroff biz 17 R1 1 May 04 2009 6 Dimensions Figure 8 Mechanical Dimensions All dimensions in millimeters mm 10007851...

Page 22: ...VXS VME64x Tower System Dimensions 10836 060 www schroff biz 18 R1 1 May 04 2009...

Page 23: ......

Page 24: ...SCHROFF GMBH www schroff biz Langenalberstr 96 100 Tel 49 0 7082 794 0 Fax 49 0 7082 794 200 D 75334 Straubenhardt...