Setting of all configuration parameters of the sensor is possible with the help of
the respective panel (
Sensor configuration parameters
):
Automatic data stream mode after power switch on
By default, after the power supply is switched on, the sensor is waiting for the
request result command. To get a continuous data stream after switching on the
power supply, tick the
Auto stream
box. Save parameters (see below). Now with
any subsequent activation of the sensor it will work in the data stream mode.
Saving parameters
•
All parameters are applied immediately after setting.
•
Perform testing of the sensor operation with new parameters.
•
To store new parameters in nonvolatile memory, execute
File > Write
to flash
. Now, with any subsequent activation of the sensor it will work
in the configuration you have selected.
Saving and writing a set of parameters