AR100 Operation Manual
© 2018 Schmitt Industries
Revision 1.1
23
time or trigger.
R
bit:
0 - window mode (default);
1 - full range.
S
bit:
0 - time sampling (default);
1 - trigger sampling.
13
Network address
1…128 (default — 1)
14
Rate of data transfer
through a serial port
1…192 (default — 4)
Specifies data transfer rate in increments of 2400
baud; e.g., 4 means the rate of 4*2400=9600 baud.
15
Number of averaged
values
1…128 (default — 1)
16
Sampling period
1) 100…65535 (default — 5000)
The time interval in increments of 1 μs with which
sensor automatically communicates the results on
streaming request (sampling mode = 0).
2) 1…65535 (default — 5000)
Divider ratio of trigger input (sampling mode = 1).
17
Maximum integration
time
3…3200 (default –
3200 μs)
18
Beginning of analog
output range
0…16383 (default — 0)
19
End of analog output
range
0…16383 (default — 16383)
20
Time lock of result
0…255
Specifies the time interval in increments of 5 ms.
21
Zero point
0…16383 (default — 0)
22-38
Reserved
39
Change the protocol
(RS interface)
0 — ACUITY protocol;
1 — ASCII protocol;
1 — MODBUS RTU protocol.
40
Save/recover the
settings
0x00AA — Save current parameters to FLASH-
memory
0x0069 — Restore the default parameters
41
Latch a current result
0 — nothing will happen;
1 — a result will be latched.
ASCII format
Data exchange with the sensor in ASCII format is carried out via the RS232 or
RS485 interfaces. The command always consists of the request code (see the