AR100 Operation Manual
© 2018 Schmitt Industries
Revision 1.1
27
Note
. If the beginning of the range of the analog signal is set at a higher value
than the end value of the range, this will change the direction of rise of the analog
signal.
Analog output operation mode
When using the ‘Window in the operating range’ function, this mode defines the
analog output operation mode.
Analog output can be:
•
in the window mode or
•
in the full mode.
"Window mode"
. The entire range of the analog output is scaled within the
selected window. Outside the window, the analog output is "0".
"Full mode"
. The entire range of the analog output is scaled within the selected
window (operating range). Outside the selected window, the whole range of the
analog output is automatically scaled onto the whole operating range of the
sensor (sensitivity range).
Factory parameters table
Parameter
Value
Range of the analog output
Measurement range of the
sensor
Analog output operation mode
Window
Parameterization program
Function
The RF60Х-SP-2.0 software is intended for:
1) Testing and demonstration of work of AR100 series sensors;
2) Setting of the sensor parameters;
3) Reception and gathering of the sensor data signals
Download link:
Program setup
Run
RF60хsetup.exe
and follow the instructions of the installation wizard.