38
Copyright © 2019 Axxiom Manufacturing, Inc.
Failure to follow the procedures below could result in serious injury or death. In addition to these
procedures completely read and understand all sections of this
Bulk AmphiBlast Operation and
Maintenance Manual
.
The closure assembly is part of a pressurized vessel. Propelled objects will cause serious injury or
death. Depressurize vessel before performing any maintenance. See Section 6.2.
6.1
Bulk AmphiBlast™ Setup Procedure (see Figure 6.2)
6.1.1. Confirm that the abrasive blaster is properly maintained and inspected as detailed in
Section 8.0.
6.1.2. Static electricity is generated by the abrasive flow through the blast hose. To minimize
the chance of static electric shock to operating personnel only use static dissipating blast
hose and install a grounding strap on the abrasive blaster.
Static electric shock hazard. To minimize the chance of static electric shock install a
grounding strap on the abrasive blaster and only use static dissipating blast hose.
6.1.3. Do Not operate this equipment without a pressure relief device in place. The ASME
Code requires that all vessels be provided with pressure relief devices. See Section 3.11.
Rupture Hazard. Operating the pressure vessel above the maximum allowable working
pressure can result in rupturing the pressure vessel. Install an air pressure relief valve to
protect against over pressurization of the blast vessel. See Section 3.11.
6.1.4. Make certain that the abrasive blaster is not pressurized. Follow the depressurizing
procedure given in Section 6.2.
Airborne particles and loud noise hazards from blowdown exhaust air can cause serious
injury and loss of hearing. Wear approved eye and ear protection. Stay clear of
blowdown air path. DO NOT place hands or other body parts in the blowdown air path.
Make sure no personnel are in the blowdown air path.
6.1.5. Properly install the manway cover (#22) and gasket (#34). See Section 6.5.
6.1.6. Verify that all required personal protective equipment is available for each operator and
in good operating condition (safety glasses, safety shoes, ear plugs, gloves, airline filter,
respirator, & carbon monoxide monitor).
Critical: Adhere to all local, state, and federal
regulations including, but not limited to, OSHA (Occupational Health and Safety
Administration). Pay close attention to requirements regarding breathing air quality.
When an oil-lubricated air compressor is used, additional requirements for a high
temperature alarm and/or a carbon monoxide monitor become necessary. See Sections
3.9 and 3.10.
Failure to use personal protective equipment could result in serious injury or death.
6.0 Pre-operation Procedures
Summary of Contents for AmphiBlast 120
Page 20: ...20 Copyright 2019 Axxiom Manufacturing Inc 2 6 b Bulk AmphiBlast Dimensional Specifications ...
Page 21: ...21 Copyright 2019 Axxiom Manufacturing Inc 2 7 Bulk AmphiBlast Strapping Packing Detail ...
Page 66: ...66 Copyright 2019 Axxiom Manufacturing Inc This page was intentionally left blank ...
Page 71: ...71 Copyright 2019 Axxiom Manufacturing Inc 9 1 d Bulk AmphiBlast Water Panel Back View ...
Page 78: ...78 Copyright 2019 Axxiom Manufacturing Inc 9 2 d Bulk AmphiBlast Water Panel Back View ...
Page 82: ...82 Copyright 2019 Axxiom Manufacturing Inc 9 3 a Vessel and Trailer Assembly ...
Page 83: ...83 Copyright 2019 Axxiom Manufacturing Inc 9 3 b Vessel and Trailer Parts List ...
Page 84: ...84 Copyright 2019 Axxiom Manufacturing Inc 9 4 Thompson Valve II with Diverter Plate ...
Page 85: ...85 Copyright 2019 Axxiom Manufacturing Inc 9 5 Automatic Air Valve normally closed ...
Page 86: ...86 Copyright 2019 Axxiom Manufacturing Inc 9 6 Control Valves Pneumatic and Electric ...
Page 87: ...87 Copyright 2019 Axxiom Manufacturing Inc 9 7 Water Control Valve ...
Page 88: ...88 Copyright 2019 Axxiom Manufacturing Inc 9 8 a G2 Pneumatic Deadman ...
Page 89: ...89 Copyright 2019 Axxiom Manufacturing Inc 9 8 b Deadman Valves Pneumatic ...
Page 91: ...91 Copyright 2019 Axxiom Manufacturing Inc 9 10 AmphiBlast Injection Module ...
Page 92: ...92 Copyright 2019 Axxiom Manufacturing Inc 9 11 Vacuum Loading System ...
Page 93: ...93 Copyright 2019 Axxiom Manufacturing Inc 9 12 Palm Detent Control Valve ...
Page 94: ...94 Copyright 2019 Axxiom Manufacturing Inc 9 13 Halok Assembly ...
Page 96: ...96 Copyright 2019 Axxiom Manufacturing Inc This page was intentionally left blank ...
Page 111: ...111 Copyright 2019 Axxiom Manufacturing Inc 14 0 Water Pump Manual ...
Page 112: ...112 Copyright 2019 Axxiom Manufacturing Inc ...
Page 113: ...113 Copyright 2019 Axxiom Manufacturing Inc ...
Page 114: ...114 Copyright 2019 Axxiom Manufacturing Inc ...
Page 115: ...115 Copyright 2019 Axxiom Manufacturing Inc ...
Page 116: ...116 Copyright 2019 Axxiom Manufacturing Inc ...