I1
Individual coding
I2
Individual coding, multiple teaching
(3)
1P2P
1 p-type diagnostic output and 2 p-type safety outputs
SD2P
serial diagnostic output and 2 p-type safety outputs
(4)
without
Power to unlock
A
Power to lock
(5)
without
Manual release
N
Emergency release
T
Emergency exit
T 8
Emergency exit, distance 8.5 mm
2.2 Special versions
For special versions, which are not listed in the ordering code, these specifications apply accordingly, provided that
they correspond to the standard version.
2.3 Purpose
The non-contact, electronic safety switchgear is designed for application in safety circuits and is used for monitoring
the position and locking of movable safety guards.
F
The safety switchgears are classified according to EN ISO 14119 as type 4 interlocking devices. Designs with individual coding
are classified as highly coded.
The different variants can be used as safety switch with interlocking function either as solenoid interlock.