Mechanical data - Connection technique
Termination
Connector M12, 8-pole, A-coded
Length of sensor chain, maximum
200 m
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing
on the output current
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31
devices in case of serial diagnostic SD
Mechanical data - Dimensions
Length of sensor
120 mm
Width of sensor
87.5 mm
Height of sensor
35 mm
Ambient conditions
Degree of protection
IP67
IP69
IP66
Ambient temperature, minimum
+0 °C
Ambient temperature, maximum
+60 °C
Storage and transport temperature, minimum
-10 °C
Storage and transport temperature, maximum
+90 °C
Relative humidity, maximum
93 %
Note (Relative humidity)
non-condensing
non-icing
Resistance to vibration to EN 60068-2-6
10 … 150 Hz, amplitude 0.35 mm
Restistance to shock
30 g / 11 ms
Protection class
III
Permissible installation altitude above sea level, maximum
2,000 m
Ambient conditions - Insulation values
Rated insulation voltage U
i
32 VDC
Rated impulse withstand voltage U
imp
0.8 kV
Overvoltage category
III
Degree of pollution to IEC/EN 60664-1
3
Electrical data
Operating voltage, minimum
20.4 VDC