Approvals - Standards
Certificates
TÜV
cULus
ECOLAB
EAC
FCC
IC
General data
Standards
EN ISO 13849-1
EN ISO 14119
EN IEC 60947-5-3
EN IEC 61508
Coding
Individual coding, multiple teaching
Coding level according to EN ISO 14119
High
Working principle
RFID
Frequency band RFID
125 kHz
Transmitter output RFID, maximum
-6 dB/m
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Gross weight
550 g
Time to readiness, maximum
5,000 ms
Duration of risk, maximum
200 ms
Reaction time, switching off safety outputs via actuator, maximum
100 ms
Reaction time, switching off safety outputs via safety inputs,
maximum
1.5 ms
General data - Features
Power to lock
Yes
Solenoid interlock monitored
Yes
Latching
Yes
Manual release
Yes
Short circuit detection
Yes
Cross-circuit detection
Yes
Series-wiring
Yes
Safety functions
Yes
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Safety classification