5
Operating
5.1 Safety Instructions
Local safety requirements are fully applicable. The following safety instructions are
complimentary to the rules in force and do not supersede the latter:
Wear safety shoes and gloves.
Never exceed the maximum lifting capacity of the device. Never exceed the
maximum lifting capacity of the crane or hoist used. Consider the weight of the
lifting device. Observe the name plate.
Do not stand below the load. Always keep clear of the load.
Never carry people or animals with the load or the lifting device itself!.
Operate only when you can view the entire working area. Look out for other
persons in the working area. Never manoeuvre loads above people.
Do not let go of the handle whilst lifting a load.
Do not pull loads to the side or drag them along with the lifting device.
Do not rip loose loads that have become jammed.
When there is a power failure put the load down immediately if possible.
Immediately leave the danger area near the load.
Apply suction and lift only to appropriate loads (check for stability and porosity).
Always keep an eye on the pressure gauge. Never lift loads when the vacuum
is below -0.6 bar. When the pointer of the pressure gauge moves into the red
danger zone below -0.6 bar, put the load down immediately.
When the warning device sounds (vacuum below -0,6 bar), put the load down
immediately.
Land workpieces only on free, level surfaces. Otherwise they can slip away
when you land them.
Land load only when it has touched down entirely and safely. Fingers away
from the load when you land it. Severe bruises!
Always distribute load evenly on the suction surfaces.
Always distribute load evenly on the suction surfaces.
Caution
The following operating steps must be checked by a qualified mechanic prior to
use of the device by the operating personnel. Correct faults before start-up.