IO-Link Data Dictionary
SMP FS RP
21.10.01.00115/00
13.03.2018
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
[email protected]
IO-Link Implementation
40
0x0028
0
2 bytes
ro
Copy of currently active process data input
64
0x0040
1
2 bytes
ro
Actual sensor value
64
0x0040
2
2 bytes
ro
Lowest measured sensor value since power-up
64
0x0040
3
2 bytes
ro
Highest measured sensor value since power-up
66
0x0042
1
2 bytes
ro
Supply voltage as measured by the device (unit: 0.1 Volt)
66
0x0042
2
2 bytes
ro
Lowest measured supply voltage since power-up
66
0x0042
3
2 bytes
ro
Highest measured supply voltage since power-up
564
0x0234
0
1 byte
ro
0x00 = SIO mode
0x10 = IO-Link revision 1.0 (set by master)
0x11 = IO-Link revision 1.1 (set by master)
140
0x008C
0
cc1
4 bytes
ro
Switch-on counter for switch point 1 (non-erasable)
141
0x008D
0
cc2
4 bytes
ro
Switch-on counter for switch point 2 (non-erasable)
143
0x008F
0
ct1
4 bytes
ro
Switch-on counter for switch point 1 (erasable)
144
0x0090
0
ct2
4 bytes
ro
Switch-on counter for switch point 2 (erasable)
32
0x0020
0
2 bytes
ro
Number of errors since last power-up
36
0x0024
0
1 byte
ro
0 = Device is operating properly
1 = Maintenance required
2 = Out of specification
3 = Functional check
4 = Failure
37
0x0025
1-15
15 x 3 bytes
ro
Information about currently pending events
Fixed-length array format according to IO-Link specification V1.1
130
0x0082
0
1 byte
ro
0 = No error
1-99 = Error code displayed by the device
138
0x008A
1
1 byte
ro
Type code of active device status (see below)
138
0x008A
2
2 bytes
ro
ID code of active device status (see below)
146
0x0092
0
Condition Monitoring
1 byte
ro
Bit 2: Leakage rate above limit -L- (not for VSi P10)
Bit 5: Primary voltage US outside of optimal range
160
0x00A0
0
Actual Leakage Rate
2 bytes
ro
Leakage rate, unit mbar/sec (not for VSi P10)
Supply Voltage
Error Count
Condition Monitoring [CM]
Sensor Value
Sensor Value HI
Monitoring
Process Data In Copy
Observation
Counter cc2
Diagnosis
Device Status
Supply Voltage LO
Sensor Value LO
Detailed Device Status
Supply Voltage HI
Counter ct1
Counter cc1
IO-Link Device Status
Communication Mode
Active Error Code
Counter ct2
Extended Device Status - Type
Extended Device Status - ID
Process Data
Communication Mode
Counters
J. Schmalz GmbH
5 of 6
VSi Data Dictionary
Summary of Contents for SCPi FS RP
Page 1: ...Compaktejector SCPi FS RP Operating Instructions WWW SCHMALZ COM EN US 30 30 01 01602 01 10 18...
Page 17: ...Technical Data EN US 30 30 01 01602 01 10 18 17 58 4 4 4 Pneumatic Circuit Plan...
Page 50: ......
Page 57: ...Notes EN US 30 30 01 01602 01 10 18 57 58 16 Notes...
Page 58: ...J Schmalz GmbH EN US 30 30 01 01602 01 10 18 Subject to technical changes without notice...