Installation
30 / 58
EN-US · 30.30.01.01602 · 01 · 10/18
7.4.1 Operating the Vacuum Switch in SIO Mode
PIN assignment, 5-pin M12 connector
M12 connector
Pin
Symbol
Function
1
U
s
Supply voltage
2
OUT2
Switching point 2, leakage monitoring (factory setting)
3
Gnd
S
Ground
4
OUT1
Switching point 1, parts control (factory setting)
5
—
Not used
The electrical connection can be established in the following ways:
1. Direct connection to the controller
Using the Schmalz connection cable, part no. 21.04.05.00080, with connector M12-5 with open end
and 5 m length.
2. Connection via an I/O box
Using the Schmalz connection cable, part no. 21.04.05.00158, with connector M12-5 on M12-5 and 1 m
length.
7.4.2 Operating the Vacuum Switch in IO-Link Mode
PIN assignment, 5-pin M12 connector
M12 connector
Pin
Symbol
Function
1
U
s
Power supply for sensor
2
—
—
3
Gnd
Ground
4
C/Q
IO-Link communication
5
—
—
Start of operations
The second output OUT2 for the vacuum switch is deactivated in IO-Link operation.
When operating the switch in IO-Link mode (digital communication), the supply voltage, Gnd and the C/Q
communication cable must be directly connected to the corresponding connections of an IO-Link master
with IO-Link class A parts. When doing so, a new port must be used on the master for each switch; a junc-
tion of several C/Q cables is not possible with only one IO-Link master port.
The IO-Link master must be connected in the configuration of the automation system in the same way as
other fieldbus components. To activate the port for IO-Link communication, a software tool from the re-
spective master manufacturer is usually provided (e.g. Siemens PCT, Beckhoff TwinCAT etc.).
Summary of Contents for SCPi FS RP
Page 1: ...Compaktejector SCPi FS RP Operating Instructions WWW SCHMALZ COM EN US 30 30 01 01602 01 10 18...
Page 17: ...Technical Data EN US 30 30 01 01602 01 10 18 17 58 4 4 4 Pneumatic Circuit Plan...
Page 50: ......
Page 57: ...Notes EN US 30 30 01 01602 01 10 18 57 58 16 Notes...
Page 58: ...J Schmalz GmbH EN US 30 30 01 01602 01 10 18 Subject to technical changes without notice...