5.3.5 Extended Functions Menu (EF)
An "Extended functions" menu (EF) is available for applications with special requirements.
1. In the basic menu, press the
or
button to select the
EF
parameter and change to the param-
eter selection of the EF menu by pressing the
button.
2. The parameters are set in accordance with the description in the Basic Menu section.
ð
The first parameter
0u1
appears on the display.
Display
code
Parameter
Explanation
0u1
Switching function,
switching output 1
Define the switching point mode:
H.no / H.nc:
Hysteresis function, normally open / normally
closed
F.no / F.nc:
Window function, normally open / normally closed
C.no / C.nc:
Condition monitoring function, normally open /
normally closed
d.no / d.nc:
Diagnosis function, normally open / normally
closed
0u2
Switching function,
switching output 2
Switching function, switching output 2: (see Ou1)
d51
Switch-on delay for
switching point 1
in ms; This parameter is not displayed in the menu if the
switching point is in condition monitoring mode C.no.
dr1
Switch-off delay for
switching point 1
In ms; This parameter is not displayed in the menu if the
switching point is in condition monitoring mode C.no.
d52
Switch-on delay for
switching point 2
In ms; This parameter is not displayed in the menu if the
switching point is in condition monitoring mode C.no.
dr2
Switch-off delay for
switching point 2
In ms; This parameter is not displayed in the menu if the
switching point is in condition monitoring mode C.no.
uni
Vacuum unit
Define the displayed vacuum unit
bAr:
Vacuum value in millibar
kPa:
Vacuum value in kilopascal
IHg:
Vacuum value in inch of mercury
PSI:
Vacuum value in pound-force per square inch
Eco
Display in ECO mode
Set the display
off:
ECO mode is deactivated – the display remains on
Lo:
Display dimmed by 50%
on:
ECO mode is activated – the display switches off
d15
Align the display
Std:
Standard
Red:
Display rotated by 180°
P1n
PIN code
Access rights, specify the PIN code, lock the menus
P-n
Signal type
Transistor functions of both outputs: PnP / nPn
rE5
Reset
No:
The values remain unchanged
YES:
Reset parameter values to factory settings
Overview of display codes in the Additional functions menu
Summary of Contents for SCPi FS RP
Page 1: ...Compaktejector SCPi FS RP Operating Instructions WWW SCHMALZ COM EN US 30 30 01 01602 01 10 18...