Functions of the Vacuum Switch
38 / 58
EN-US · 30.30.01.01602 · 01 · 10/18
The average switching frequency of the air saving function can be determined using the difference be-
tween counters 1 and 2.
The erasable counters ct1 and ct2 can be reset to 0 during operation via IO-Link by using the appropriate
system commands.
In the operating menu, this is possible via the INF menu and the parameter
rct
.
The storage of the non-erasable counter readings only occurs every 500 steps. That means that when the
operating voltage is switched off, up to 499 steps of the counter are lost.
8.10.3 Status Signals
The current status of the ejector, i.e. whether errors or warnings are active, can be queried in various
ways:
•
Using the standard "Device status," "Detailed device status" and "Error count" IO-Link parameters
•
Using the "Active error code" and "Condition monitoring" parameters
•
Using the "Extended device status," which transmits the entire display of the device status with clas-
sification of the severity level of errors and warnings.
8.10.4 Leakage Measurement
If one of the switching points for the vacuum switch is set to Condition monitoring mode, the actual leak-
age measured can be read in millibars per second.
8.11 System Commands
8.11.1 Resetting to Factory Settings
All adjustable parameters for the vacuum switch are reset to factory settings using this function.
WARNING
By activating/deactivating the product, output signals lead to an action in the pro-
duction process!
Personal injury
4
Avoid possible danger zone.
4
Remain vigilant.
The function is executed in the EF menu under the parameter
re5
or via IO-Link:
1. Press the
button.
ð
When the menu is locked, enter the valid PIN code.
2. Use the
or
button to select the menu item
EF
.
3. Confirm using the
button.
ð
0u1
appears on the display.
4. Use the
button to select the parameter
re5
.
5. Press the
button.
ð
YE5
appears on the display.
6. Press the
button again.
ð
The vacuum switch is reset to the factory settings.
ð
The display flashes briefly and then returns to the display mode.
Summary of Contents for SCPi FS RP
Page 1: ...Compaktejector SCPi FS RP Operating Instructions WWW SCHMALZ COM EN US 30 30 01 01602 01 10 18...
Page 17: ...Technical Data EN US 30 30 01 01602 01 10 18 17 58 4 4 4 Pneumatic Circuit Plan...
Page 50: ......
Page 57: ...Notes EN US 30 30 01 01602 01 10 18 57 58 16 Notes...
Page 58: ...J Schmalz GmbH EN US 30 30 01 01602 01 10 18 Subject to technical changes without notice...