INSTALLATION
30.30.01.00174/06
www.schmalz.com
EN | 29
5.3.1.2 Additional dust filter
Install the additional filter in the vacuum connection of the pump using the
attachment parts. Screw the hose nozzle (with sealing) for the hose connection to
the dust filter.
EVE 40
EVE 50
EVE 80
5.3.1.3 Vacuum regulation valve
5.3.2 Ejector
The dynamics of the vacuum tube lifter
J
UMBO
F
LEX
can be set by
installing a vacuum regulation valve (VRV).
Install the ejector as per the diagram
(
J
UMBO
F
LEX
20/35)
.
Retrofitting an electrical pump onto a pneumatic ejector:
Remove the hose nozzle and the suspension eye on the rotary union.
Screw the suction side of the ejector at the top, with the mounting
plate and handle, into the rotary union (with sealing). Attach the
pressure-limiting valve (PLV) on the side connection. Secure the
compressed air supply hose to the hose nozzle on the ejector using
the hose clamp provided.
Make sure that the pressure generated is consistent with the
requirements of the ejector (for air volume and operating pressure,
see the documentation for the vacuum generator).