PRODUCT DESCRIPTION
22 | EN
www.schmalz.com
30.30.01.00174/06
2.10.6 Schmalz Blower Box (SBB)
ATTENTION
Overheating risk
If there is an insufficient supply of fresh air, the blower will overheat and
become damaged.
►
Only use the blower or silencer box (SBB) without additional cooling up to an
ambient temperature of max. 40°C.
►
It is important to ensure that the side opening has an unobstructed supply of
fresh air (motor intake air).
Recommended distance: 20 cm in all directions.
2.10.7 Storage rack
2.10.8 Crane suspension
2.10.9 Vacuum regulation valve (VRV)
The Schmalz Blower Box surrounds the vacuum pump and uses
sound-dampening material to reduce the noise level to approx. 65 db
(A).
The silencer box SBB also protects the blower from exterior soiling.
Using the storage rack for the vacuum tube lifter
J
UMBO
F
LEX
, you can
safely deposit the tube lifter and protect the suction pads of the tube
lifter when doing so.
The crane suspension for the tube lifter can be adjusted for all lift
capacity ranges. It allows you to suspend the tube lifter at exactly the
height required.
Secondary air can be introduced into the system using the vacuum
regulation valve, which lets you adjust the dynamic properties of the
tube lifter.