Installation
84 / 94
EN-US · 30.30.01.02237 · 00 · 04/20
PIN Assignment, M12 Socket, A-Coded
M12-A socket
PIN
Symbol
Wire
color
1)
Function
3
2
4
1
5
1
L+
Brown
Supply voltage for sensor
2
UA / DO
White
Supply voltage for actuator and digi-
tal output
3
GND
s
Blue
Sensor ground
4
IO-Link / DI /
DO
Black
IO-Link and digital input/output
5
GND
A
Gray
Actuator ground
1)
When using a Schmalz connection cable (see accessories)
8.4.4 DI module
Mounting the Connection Cable
Connect the connection cable to the DI module.
The figure shown here is an example. Depending on the design of the terminal, one to six DI modules are
installed.
DI module
Port X1
Port X2
Port X3
Port X4
ü
Prepare the connection cable.
4
Connect the connection cable to one of the four 5-pin M12 sockets (Port X1 to X4) on the DI module
and tighten the union nut with the max. tightening torque (hand-tight).
PIN Assignment, M12 Socket, A-Coded
M12-A socket
PIN
Symbol
Wire
color
1)
Function
3
2
4
1
5
1
U
S
Brown
Supply voltage for sensor
2
DI 2
White
Digital input 2
3
GND
s
Blue
Sensor ground
4
DI 1
Black
Digital input 1
5
n.c.
Gray
Not connected
1)
When using a Schmalz connection cable (see accessories)