Technical Data
EN-US · 30.30.01.02237 · 00 · 04/20
23 / 94
4 Technical Data
4.1 Operation and Storage Conditions
Operating medium
Air or neutral gas
5 µm filtered
Oiled or unoiled
Class 3-3-3 compressed air quality acc. to ISO 8573-1
Operating pressure (flow pres-
sure)
3 to 6 bar (optimally 4 to 5 bar)
Max. dynamic pressure
6.8 bar
Working temperature
0 to 50° C
Storage temperature
–10 to 60° C
Permitted air humidity
10 to 90% RH (free from condensation)
Precision of vacuum sensor
± 3% FS (full scale)
4.2 Electrical and Technical Parameters
Supply voltage for sensor
24 V –20 to +10% VDC
(PELV
1)
)
—
Max. permitted power consumption for
sensor supply voltage
24 V
5 A
Supply voltage for actuator
24 V –20 to +10% VDC
(PELV
1)
)
—
Max. permitted power consumption for
actuator supply voltage
24 V
16 A
Typ.
Max. every
500 ms for 25
ms
Power consumption
2)
for sensor supply
voltage (at 24 V)
Bus module
100 mA
—
1 x NC ejector
10 mA
—
1 x NO ejector
10 mA
—
1 x IMP ejector
10 mA
—
1 x DI module
12 mA
—
1 x IO-Link master
30 mA
—
Power consumption
2)
for actuator sup-
ply voltage (at 24 V)
Bus module
10 mA
—
1 x NC ejector (suction and
release)
20 mA
30 mA
1 x NO ejector (no suction /
release)
20 mA /
30 mA
40 mA /
60 mA
1 x IMP ejector (no suction /
release)
10 mA /
30 mA
10 mA /
40 mA
1 x IO-Link master
25 mA
—
Polarity reversal protection
Yes, all M12 connector connections
Degree of protection
IP 65
NFC
NFC Forum Tag type 4
IO-Link master
Maximum permitted output current I_L
+
(Pin 1)
400 mA