SAFETY INSTRUCTIONS 

6 |   EN 

www.schmalz.com 

30.30.01.00159/01 

1.4  General safety instructions 

 

 

WARNING 

 

 

 

Ignoring the general safety guidelines 

 

Personal injury / damage to plants or systems 

►  The operating and maintenance instructions contain important information on 

using the system. All users must have read and understood the operating and 
maintenance instructions and keep them for later reference.

 

 

►  These operating and maintenance instructions are specific to the items included 

in delivery from Schmalz. They do not take into account any modifications to the 
system made by the customer, which are strictly prohibited. 

►  The system may only be connected and operations started once the operating 

and maintenance instructions have been read and understood. 

►  Use only the connections, mounting holes and attachment materials that have 

been provided. 

►  Carry out mounting or removal only when the device is in an idle, depressurized 

state. 

►  Only qualified specialist personnel and mechanics may perform the installation, 

maintenance and repair work. Qualified specialist personnel are persons who 
have received technical training and have the knowledge and experience 

– 

including knowledge of applicable regulations 

– necessary to enable them to 

recognize possible dangers and implement the appropriate safety measures 
while performing tasks. 

►  General safety regulations, European standards and VDE guidelines must be 

observed and complied with. 

►  Personnel and animals are not permitted to sit or stand in the danger zone 

area. 

►  You are responsible for third parties in the working area of the system. In view 

of this, responsibilities for the various tasks to be carried out on the system 
must be clearly specified and adhered to.  

►  Protect the components from damage of any kind. 

 

 

All applicable laws and regulations must be adhered to at all times. 

When using the system, observe the statutory regulations, safety regulations, 
standards and guidelines applicable at the location of use.  
Check with the competent authorities for more information.  
The safety instructions in these operating and maintenance instructions do not 
replace these laws and regulations, but are to be regarded as a supplement to 
them. 

Summary of Contents for Blower Box SBB

Page 1: ...www schmalz com Ergonomic Handling Solutions EN Operating and maintenance instructions Schmalz Blower Box SBB 30 30 01 00159 01 03 2016...

Page 2: ...retains the rights established thereby Reproduction of the contents in full or in part is only permitted within the limits of the legal provisions of copyright law Any modifications to or abridgments...

Page 3: ...t Description 10 2 1 Schmalz Blower Box components 10 2 2 Type plate 10 3 Technical Data 11 4 Delivery Packaging and Transport 12 4 1 Delivery 12 4 2 Packaging 12 4 3 Transport with mounted vacuum gen...

Page 4: ...g This warning informs the user of a risk that could result in death or serious injury if it is not avoided WARNING Type and source of danger Consequence Remedial action Caution This warning informs t...

Page 5: ...l Description General warning symbol Explosive atmosphere Electrical voltage Flying debris Hot surfaces 1 3 Mandatory symbols Explanation of the mandatory symbols used in the operating and maintenance...

Page 6: ...the installation maintenance and repair work Qualified specialist personnel are persons who have received technical training and have the knowledge and experience including knowledge of applicable reg...

Page 7: ...ment must be carried out by qualified electrical specialists only A qualified employee is defined as an employee who has received technical training and has the knowledge and experience including know...

Page 8: ...ature must lie within a range of 0 C to 40 C the components are installed or stored in a dry state and must be protected from splashing or dripping water no small parts can enter the exhaust air or ai...

Page 9: ...jury All vacuum generators generate an exhaust air flow Depending on the purity of the ambient air this exhaust air can contain particles which escape from the exhaust air outlet at high speed potenti...

Page 10: ...ose duct 2 Cover 5 Exhaust air channel external ventilator for V model 3 Cable connection 2 2 Type plate The device type device number and year of manufacture are specified on the type plate This info...

Page 11: ...650 Width mm 575 Height mm 565 Weight kg 27 7 without vacuum generator may vary depending on the design For the vacuum pump EVE TR 40 50Hz the silencer box enables a reduction in the noise emissions...

Page 12: ...rted either in a cardboard box or wooden crate or on a pallet The packaging material must be disposed of in accordance with country specific laws and guidelines Labeled transport aids and safety mecha...

Page 13: ...AND TRANSPORT 30 30 01 00159 01 www schmalz com EN 13 CAUTION Load suspension outside the center of gravity May cause damage to the screw union between pump and metal tray Sudden and incorrect lifting...

Page 14: ...2 and size 36 Image Work step description 1 1 Remove the cover from the Schmalz Blower Box 2 Position the base plate at the intended installation location Important If the Schmalz Blower Box is used t...

Page 15: ...acuum hose without voltage through the opening in the front side of the base tub 3 Attach the vacuum hose to the suction supports with a hose clamp 4 Mount optional dust filter see section 5 4 6 1 Att...

Page 16: ...2 Fit motor sleeve over motor 3 1 Fit additional sound absorber with the large bore hole over the exhaust air silencer 2 Ensure that the foam insert contacts the housing wall of the sound absorber cor...

Page 17: ...commissioning Check whether the exhaust air exits from the side of the base plate when the blower is switched on No exhaust air should enter the interior from the blower silencer 9 1 Place the cover...

Page 18: ...3 Installing on a blower console 5 3 1 Vacuum pump 5 3 2 Vacuum blower Installation as for vacuum pump See also mounting instructions for blower console 30 30 01 00881 Installation on the blower cons...

Page 19: ...rations check that the vacuum generator rotation direction corresponds with that in the operating instructions provided separately Ensure that the Schmalz Blower Box is securely screwed to the support...

Page 20: ...Description of Operation The Schmalz Blower Box allows the noise emissions caused by the vacuum generator to be reduced to a minimum The cover must be properly closed during the operation of the vacu...

Page 21: ...Switch off the vacuum generator and disconnect from the electrical voltage 2 Remove the vacuum supply hose 8 2 Disposal Only qualified specialist personal may prepare the Schmalz Blower Box for dispos...

Page 22: ...and maintenance instructions and CAD data and get comprehensive information about our products and services www schmalz com dokumentationen How to videos In short easy to understand videos we explain...

Reviews: