OPERATING INSTRUCTIONS
1
8
CG700 rondo
Version: 27202 -
D
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
4.14.3
Face plate assembly installation / Pre-fabricated pool and
Wooden-liner pool
After connecting the air button, put on the face plate assembly (35/35.1), this allows the
pressure connection and air connection to slide into one another. Fasten to the clamp ring
(22) with the screws (90).
5
Electrical connections
5.1
Electrical Connections - general
The electrical connections to the counter-current swimming system must be carried out by
a specialised company in the electrical engineering branch approved by the local energy
provider, taking into account the technical connection requirements.
fig. 27: Pre-fabricated pool
fig. 28: Wooden-liner pool
20
Housing
21
Switching tube
22
Clamp ring
35/35.1
Face plate assembly
90
Screw
Warning!
Make sure that there is not a kink in the switching tube (21), do not lay it in a
loop and do not shorten it!
Warning! Mortal danger!
The connections must be carried out by a qualified electrician. For this see for
example the
Technical Connection Conditions for heavy current from the
local power supply company
, the
Regulations of the Electrical Trade
VBG (§3)
and
DIN VDE 1000-10 / 1995-5.
The relevant
DIN VDE directives
0100
and where there is a risk of explosion
0165
must also be observed. If the
installation is not carried out properly, there is a risk of getting electric shocks!
Warning!
Compare the available power supply voltage with the details on the motor’s
factory plate and select the appropriate switching.
We recommend the use of a motor protection facility. Connect the motor in
accordance with the circuit diagrams in the following chapters.
8235
8234