OPERATING INSTRUCTIONS
15
CG700 rondo
Version: 27202 -
D
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
4.11
Connection to the pump
4.12
Installing the switchgear cabinet
fig. 21
01
Motor
12
Air pipe clamp
13
Hose line pressure side
16
Hose line suction side
Connect the hose lines (13 pressure side
+ 16 suction side) to the pump body. Use
the corresponding air pipe clamps (12)
on both sides for this.
Warning!
Make sure that the connections
from the
body of the pump to the installation kit /
pipework are as nearly aligned as is
possible.
The hose lines must always be attached
to the pump on the one side
(compensator function), see diagram.
fig. 22
K
Protective hose
02
Switchgear cabinet
31
Switching tube
Mount the switchgear cabinet (02) as
close as possible to the installation kit.
Also please observe the instructions in
chapter 4.2.
Fix the switching tube (31) onto the
nipple in the protective hose (K).
Warning!
Be careful not to put a kink in the
switching tube and keep it as short as
possible, maximum length 8 m.
8228
8229