General handling / operation
26 | 52
Operating Manual | Edition 1.00 (08-2020) | ACO 08
Specified fault limit exceeded. If configured in
the setup, the error must be acknowledged on
user level 1 by entering the password.
Acknowledgment without password is possible
on user level 2 or 3.
7.2.3
Teaching
Before the monitoring status can be started, a reference curve must be formed from one or several
good crimps. The number of reference crimps is defined in setup.
1.
To access the teaching mode, select the
“teaching” tile on the main menu (possibly
requires user level 2 or 3 if configured in
setup).
2.
Produce a reference crimp on the crimping
machine and use it to verify the quality
criteria (e.g. crimp height, pull-off
strength/cross section) and confirm with
“OK” if prompted.
If the crimp does not meet the quality
criteria, use “discard” to reject it.
3.
If a curve deviates too much from the
previous curves, the message “invalid Ref”
appears automatically. Select “OK” to
generate the last curve again or “discard”
to start over with teaching.
Summary of Contents for ACO 08
Page 1: ...ACO 08 Crimp Force Monitor Operating manual Edition 1 00 08 2020...
Page 46: ...Exploded drawings 46 52 Operating Manual Edition 1 00 08 2020 ACO 08 12 EXPLODED DRAWINGS...
Page 47: ...Block diagram Operating Manual Edition 1 00 08 2020 ACO 08 47 52 13 BLOCK DIAGRAM...
Page 48: ...PLC Interface 48 52 Operating Manual Edition 1 00 08 2020 ACO 08 14 PLC INTERFACE...
Page 49: ...PLC Interface Operating Manual Edition 1 00 08 2020 ACO 08 49 52...
Page 50: ...Notes 50 52 Operating Manual Edition 1 00 08 2020 ACO 08 15 NOTES...
Page 52: ...Index 52 52 Operating Manual Edition 1 00 08 2020 ACO 08...