25
/
33
5.4. Mounting the purlin connectors (optional)
Fasten each purlin connector with
four hexagon head bolts M12x30
DIN933, washers DIN9021 and
fl ange nuts M12 DIN6923 to the
module-bearing rail.
Fig. 5.5.-1 (mounting the purlin connector)
1.
1.
5.5. Mounting the module clamp adapter (optional)
When mounting the purlin connectors, please use the designated drilled holes on the module-bearing rails!
NOTICE
Please ensure that no drilling chips are left in the module-bearing rails after screwing the self-drilling screws
to avoid contact corrosion!
After positioning the module clamp adapter, please clean the module-bearing rails with a hand brush or
cover the module-bearing rail during the screwing process (e.g. with a cardboard).
The module clamp adapter must be used in the case of a horizontal bearing of the modules or when using a
combined clamping. Moreover, the module clamp adapter is used when the modules are mounted vertically
(in portrait), in combination with Rapid 2+ or Standard clamps.
The exact positions of the module clamp adapters can be referenced in the
technical
general layout drawing
.
Schletter Solar GmbH – Alustraße 1 – 83527 Kirchdorf
Mounting instruction
FS UNO
with SRF Foundation Posts
| 2016.09 V.00