12.3 Parameters for BWS in combination with weighing beams and as weighing platform
To set parameters, turn on the scale.
Press
key during the self-checking.
Display will show “pn”.
Press
,
and
to enter, display will show “po chk”.
Menu
Sub Menu
Description
P 0 chk
Set H
Set high limit for check weighing
Set lo
Set low limit for check weighing
beep
No
No beep for check weighing
Ok
Beep, when check weighing within limits
ng
Beep, when check weighing outside limits
P1 ref
A 2n 0
Automatic zero tracking
Options: 0 .5d ,1 d,, 2 d , 4 d
0auto
Zero setting range, after resetting the scale to zero.
Options: 0 , 2 , 5 ,10 , 20 , 50 , 100
0range
Manual zero setting range.
Options: 0 , 2 , 5 ,10 , 20 , 50 , 100
0tare
Auto zero tracking for NET mode.
(After pressing tare, NET weight will be zero)
Option: on / off
Speed
Set the ADC speed
Option: 7.5 / 15 / 3 0 / 60
Zero
Set new zero point
P 2 com
Mode
This option is used to set accumulation and RS-232
communication
Options:
Cont
: Continue data sending
St 1
: Send data once, when stable.
St c
: Send data continuously, when stable
P r1
: Send data once, when print key is pressed
(in printer mode)
Pr 2
: Send data to print and accumulation,
when
key is pressed
Auto
: Auto accumulate and auto print mode.
When weight is stable, return to zero.
Ask
: Ask mode,
Command R: read data
Command T: Tare
Command Z: Zero
Wireles : Wireless mode (wireless communication)
Kit 1
:
Baud
To set the baud rate.