41
P4 oth
Lock
To set keypad lock
Options: on / off
anm
on
Rag
1 / 2 / 5 /10 /15 / 20 / 25 / 50
tim
10 / 20/ 30/ 40/ 50/ 60/ 70/ 80/ 90
nlk
1 / 2 / 5 /10 /15 / 20 / 25 / 50
off
To turn animal function on or off
Ps unit
Kg / lb lb-oz / tj / hj
To set unit.
Options; on / Off . When the unit option is on, that unit
can be active. Tj and Hj cannot be used at the same
time.
P 6 xcl
External calibration
P7 rst
To reset the parameter back to the factory settings
P8 uw b
U w b
On
To turn Bluetooth function on or off
off
13. Error Codes
Error Message
Description
Solution
-----
Maximum load exceeded
Unload or reduce weight
Err 1
Incorrect date
Enter the date using format
“yy:mm:dd”
Err 2
Incorrect time
Enter the time using format
“hh:mm:ss”
Err 4
Zero setting error
Zero setting range exceeded due to
switching on. (4% max)
Make sure platform is empty.
Err 5
Key board error
Check the keys and connectors.
Err 6
A/D value out of range
Make sure platform is empty and check
that pan is installed properly. Check the
load cell connectors.
Err 9
Unstable Reading
Check any air variation, vibration, RF
noise and points of contact.
Check the load cell connectors.
Err 17
Tare out of range
Remove the load and restart scale.
--ol--
Over range
Remove the load.
Re-calibrate
Fai l h / fai l l
Calibration Error
Re-calibrate
Err p
Printer error
Check the printer and settings
Ba lo / lo ba
Battery low
Recharge battery, check the voltages.
Summary of Contents for 4309606
Page 2: ...2 ...
Page 33: ...33 Pr 2 Send data to print and accumulation ...
Page 64: ...64 beschädigt ...
Page 128: ...128 ...