Connection to a Fluebox
ILFE FLUE BOX
For use with Inset Live Fuel Effect gas fires complying to BS
7977-1, with a heat output not exceeding 7kw.
LARGE FLUE BOX FOR BACK BOILER
Adjustable in depth from 358mm - 480mm to accommodate
a wide range of back boilers. Suitable for fires complying with
BS 7977-2. Universal opening allowing connection to the boiler
with B Vent or Flex.
ILFE Flue Box
Large Flue Box
for back boiler
437
489
390
A
417
565
642
546
358
to
480
603
356
GF FLUE BOX
Single wall design with sloping back to help fit some openings.
For radiant gas fires complying with BS7977-1.
VRV TWIN WALL FLUE BOX
Twin wall construction for reduced condensation. Otherwise
as VRV Single Skin Box.
VRV SINGLE SKIN FLUE BOX
Suitable for fires complying with BS7977-1. Fits most pop-
ular radiant gas fires including the widely used Valor Firelite
Oxysafe. Reduced height, extra depth and extra large flanges
minimise builders work on installation.
538
375
290
415
GF Flue Box
VRV Twin Wall
Flue Box
380
100
290
520
400
280
500
500
570
VRV Single Skin
Flue Box
90
280
500
585
380
500
Flex Ø
Dim A
125
122
180
149