![Schiedel TecnoFlex Plus Installation Instructions Manual Download Page 20](http://html1.mh-extra.com/html/schiedel/tecnoflex-plus/tecnoflex-plus_installation-instructions-manual_1211851020.webp)
20
Connection to a Fluebox
Fig. 1
Typical Triplelock Installation
When connecting to a Schiedel Rite-Vent fluebox, example Fig.1, the
flexible liner simply pushes directly on to the fast fix spigot. No sealant
is required.
Standard Flue Box
Designed for use with radiant and decorative gas fires com-
plying to BS 7977-1. Constructed with an aluminium liner and
coated steel outer case.
Recessed Flue Box
Designed with the spigot at the rear, for use with larger radiant
and decorative gas fires. for gas fires to BS 7977-1.
460
560
610
196
406
165
104
Standard Flue Box
Recessed Flue Box
460
560
330
406
100
610
305
1
- Detach spigot from the fluebox.
- Push box straight back into opening.
- Screw flange face to wall.
2
- Lowering from top of chimney.
- Pull flex into flue box interior using nose
cone and string provided.
- Remove nose cone.
- Push fit Fast-fix spigot onto flex, which
will be secured by the unique clip fastening.
3
- Push spigot back into aperture in box top.
- Secure spigot using bolts provided.
- Complete installation by fitting clamp
plate and terminal.
Triplelock
Liner
Debris
Plate
Flue
Box
Suitable hearth
complying with
Building Regulations