![Schiedel TecnoFlex Plus Installation Instructions Manual Download Page 15](http://html1.mh-extra.com/html/schiedel/tecnoflex-plus/tecnoflex-plus_installation-instructions-manual_1211851015.webp)
15
CE Approved Adaptor Range
Adaptor and
Increasing Adaptor
Plain End to
TecnoFlex Plus
Extended Adaptor
Plain End to
TecnoFlex Plus
Bottom/Intermediate
Support
Gather Unit
Closure Plate
Adaptor Kit
* CE approved to EN1856-2
*ADAPTOR AND INCREASING ADAPTOR PLAIN END
TO TECNOFLEX PLUS
The adaptor is attached to the TecnoFlex Plus (see Fig. 7
opposite) by screwing the adaptor in a clockwise direction
until the edge of the TecnoFlex Plus is located between the
liner and the threaded outer wall of this component. On
high temperature applications, no sealant is required on the
screwfit joint. The plain end of the adaptor protrudes through
the hole in the closure plate at the base of the chimney stack.
The protruding end of the adaptor then fits inside the vitreous
enamel or stainless steel stove pipe. This joint between the
plain spigot and the stove pipe should be sealed with fire
cement/rope or appropriate high temperature sealant.
*EXTENDED ADAPTOR PLAIN END TO TECNOFLEX
PLUS
Installed as per adaptor Plain End to TecnoFlex Plus.
*CLOSURE PLATE ADAPTOR KIT
Available in two styles: One and two piece.
The two piece consists of two parts, a ring and an extended
plain end to TecnoFlex Plus adaptor, this adaptor is fitted as
per the adaptor plain end to TecnoFlex Plus. The ring is then
slid up around the spigot and fastened to the underside of the
closure plate to provide a neat aesthetic finish on site (see Fig.
8 opposite).
The one piece consists of a plain end to Tecnoflex Plus adaptor
and a fixed ring, this adaptor is fitted as per the adaptor plain
end to TecnoFlex Plus, fastened to the underside of the closure
plate to provide a neat aesthetic finish on site.
GATHER UNIT
The TecnoFlex Plus is fastened inside the socket protruding
from the top of the gather unit and the joint sealed using fire
cement/rope or appropriate high temperature sealant. The
gather should then be fixed to the inside of the masonry
chimney to create a seal with the chimney wall (See Fig. 9
opposite).
BOTTOM/INTERMEDIATE SUPPORT
The support bracket is used to fasten the liner to the wall of
the masonry chimney, to prevent lateral movement during
sweeping of the chimney (See Fig. 8, 9 & 10 opposite).