10
Installation Instructions
INCREASER
This component is used to increase from one diameter to the
next diameter (e.g.) 125mm to 150mm.The component is fitted
in the same way as a standard pipe length.
ADJUSTABLE PIPE
(Length 200mm with 70mm adjustment)
The adjustable pipe allows for an appliance to be removed
for cleaning and servicing. It should be positioned immediately
below the adaptor from Prima Smooth to TecnoFlex Plus, Eco
ICID or ICS. It is fitted by sliding the male spigot 50mm inside
the preceding pipe. The 50mm mark is indicated by a bead on
the male spigot.The joint is then secured by using the cover
band, which is supplied with the article. When the appliance
has to be moved, remove the adj. pipe cover band and slide
the adj. pipe down inside the previous pipe until the socket is
clear of the spigot of the adaptor above it.The appliance can
then be removed safely. It is refitted after servicing by sliding
the adjustable pipe back up to fully engage with spigot of the
adaptor above it and the cover band should then be refitted
and fastened tightly in place.
Max Adj.
70mm
50mm
Engagement
Bead
Adj. Pipe
Standard Pipe
Appliance
Connector
Appliance
Spigot
ADJUSTABLE PIPE
(Length 500mm with 50mm-370mm adjustment)
The standard adjustable pipe is installed by sliding the male spigot
a minimum of 50mm and a max of 370mm into the preceding
pipe. The locking band, which is provided with each adjustable
pipe is then fastened in place using the nut and bolt.
INSPECTION LENGTH
The inspection lengths are components providing the facility
for flue inspection and cleaning. They are installed as per a
standard pipe section.
Max Adj.
370mm
50mm
Engagement
Bead