www.scheppach.com
+(49)-08223-4002-99
+(49)-08223-4002-58
25 І 36
• Use the tool that is recommended in this manual. In
doing so, your saw provides optimal performance.
• Hands may never enter the processing zone when the
machine is in operation. Release the handle button
and switch off the machine prior to any operations.
Prior to any adjustment, maintenance or service work
disconnect the mains power plug!
Technical Data
AC motor
230 V~ 50Hz
performance
1100 Watt
operating mode
S1
Idle speed
4750 min
-1
Hard-metal blade
ø 270 x ø 30 x 2,7 mm
Number of teeth
18
Thickness riving knife
2,3 mm
table size
540x400 mm
Cutting height max. 90°
60 mm
Cutting height max. 45°
40 mm
height adjustment
0 - 60 mm
saw blade swivel
0 - 45°
suction port
ø 100 mm
weight
75 kg
Noise values
The total noise values determined in accordance with
EN 61029.
sound pressure level L
pA
86,5 dB(A)
uncertainty K
pA
3 dB
sound power level L
WA
95,7 dB(A)
uncertainty K
WA
3 dB
Wear hearing protection.
The effects of noise can cause a loss of hearing. Total
vibration values (vector sum - three directions) deter-
mined in accordance with EN 61029
.
Before starting the equipment
•
All covers and safety devices have to be properly fit
-
ted before the equipment is switched on.
• It must be possible for the blade to run freely.
• When working with wood that has been processed
before, watch out for foreign bodies such as nails or
screws, etc.
• Before you press the ON/OFF switch check that the
saw blade is fitted correctly. Moving parts must run
smoothly.
• Before you connect the equipment to the power sup-
ply make sure the data on the rating plate are dentical
to the mains data.
• Connect the machine to a properly installed protec-
tive contact socket, with at least 16A circuit breaker.
• Switch off the machine to troubleshoot or remo-
ve jammed pieces of wood. -
Disconnect the
main power plug
-
•
Refitting, including adjusting and measuring
works, and cleaning must be carried out only
when the motor is switched off. -
Disconnect
the main power plug
-
• Before switching on again, ensure that keys
and adjustment tools have been removed.
Warning!
This electric tool generates an electromag-
netic field during operation. This field can impair active
or passive medical implants under certain conditions. In
order to prevent the risk of serious or deadly injuries, we
recommend that persons with medical implants consult
with their physician and the manufacturer of the medical
implant prior to operating the electric tool.
Safety Instructions for the Handling of Saw Blades
1
Only use insertion tools if you have mastered their
use.
2
Observe the maximum speed. The maximum
speed specified on the insertion tool may not be
exceeded. If specified, observe the speed range.
3
Observe the motor / saw blade direction of rota-
tion.
4
Do not use any insertion tools with cracks. Sort out
cracked insertion tools. Repairs are not permitted.
5
Clean grease, oil and water off of the clamping
surfaces.
6
Do not use any loose reducing rings or bushes for
the reducing of holes on saw blades.
7
Make sure that fixed reducer rings for securing the
insertion tool have the same diameter and have at
least 1/3 of the cutting diameter.
8
Make sure that fixed reducer rings are parallel to
each other.
9
Handle insertion tool with caution. They are ideally
stored in the originally package or special contain-
ers. Wear protective gloves in order to improve
grip and to further reduce the risk of injury.
10
Prior to the use of insertion tools, make sure that
all protective devices are properly fastened.
11
Prior to use, make sure that the insertion tool
meets the technical requirements of this electric
tool and is properly fastened.
12
Only use the supplied saw blade for sawing opera-
tions in wood, materials similar to wood, plastics
and non-ferrous metals (except for magnesium and
alloys containing magnesium).
Residual risks
The machine has been built according to the state of
the art and the recognised technical safety require-
ments. However, individual residual risks can arise
during operation.
• Health hazard due to electrical power, with the use of
improper electrical connection cables.
• Furthermore, despite all precautions having been met,
some non-obvious residual risks may still remain.
• Residual risks can be minimised if the „safety instruc-
tions“ and the „Proper use“ are observed along with
the whole of the operating instructions.
• Do not load the machine unnecessarily: excessive
pressure when sawing will quickly damage the saw
blade, which results in reduced output of the machine
in the processing and in cut precision.
• Avoid accidental starting of the machine: the oper-
ating button may not be pressed when inserting the
plug in an outlet.
Summary of Contents for 5901309903
Page 8: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 28 29 8 36 30...
Page 9: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 9 36...
Page 20: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 20 36...
Page 30: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 30 36...
Page 31: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 31 36...
Page 32: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 32 36...
Page 33: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 33 36...