5
– FUNCTIONING AND USE
COD: 500M380.D.2018
EN
THE PRESENT MANUAL BELONGS TO -
Schenker Italia
- ALL RIGHTS RESERVED
35
MENU OPTIONS
•
WORKING TIME (timer)
It allows to select the working time of the watermaker (1-6 hours). The timer is activated if the START button
is pushed for more than 3 seconds only.
•
BY-PASS
It allows to exclude the sensor (signal pressure switch) that detects the correct cycling of the ERS. The
operation with the by-pass is necessary only in case of malfunctioning of the signal pressure switch (in
example if the system gets block,
with the message “
SYSTEM BLOCKED
”, not as consequence of a real
hydraulic problem, but just as consequence of the malfunctioning of the probe).
The bypass is used also during special operation like the shut down procedure (washing with chemicals).
The bypass activation is automatically removed after one single production cycle.
Don’t activate the by-pass
if not necessary.
•
AUTOMATIC START-UP
This function activates automatically the first start up procedure. The procedure is necessary when a new
machine is started for the first time, or after the filter cartridge replacement, or a general service. The
procedure allows to purge completely the air from the system, and from the seawater and the washing fresh
water hoses. The depressurization valve must be opened before start the procedure.