MP-000022 - A
•
To gain access to these set points remove the top front panels;
•
In figure "A" Thermocouples are a factory fitted part in a fixed position 1cm above the pilot
tube & shall not be altered from the design position.
•
In figure "B" is the adjustment of the air aeration of the burners considering Universal LPG;
this is the regulation provided by the manufacturer when you order Universal LPG gas.
•
In figure "C" is the adjustment of the air aeration of the burners considering Natural Gas;
this is the regulation provided by the manufacturer when you order this unit for Natural gas.
•
Observe if the flame is totally blue this is the ideal point of burning and better performance
of your barbecue;