MP-000022 - A
PILOTS/BURNERS LIGHTING PROCEDURE:
1
– Turn the gas control knob of the Pilot to OPEN/ON position;
2
– Keep the red button pressed which open the gas flow through the Automatic Shut off gas
valve. Hold the red button down and press the Ignition button several times until pilot is on.
3
– Keep the red button for about 1 minute, this way the gas will take all air out from tubes.
When the gas knob in release, the pilot flame should continue to burn (If not, repeat the
above step);
4
– Rotate the gas burners control knob to OPEN/ON position;
5
– Allow 5 minute complete shutoff period before the appliance is relighted.
WATER AND GAS INSTALLATION
•
All components for gas and hydraulic supply must be purchased separately by the
customer, the gas valve is attached to the grill and must not be removed or replaced with
another model.
“A” Gas inlet pipe 3/4”BSPT.
“B” Power Electrical Cord.
“C” Water inlet ½” BSP.
NOTE: Machine length up to 1m has one gas inlet, machines length bigger than 1m have
two gas inlets