Instruction Manual and Installation Instructions LAS 1218-2
16
Date: 06.11.2014
810.523 BA / EN
2.3.2 Mains connection
Y
DANGER!
230V mains voltage carrying parts.
Danger of death due to electric shock or fire:
F
Only carry out electrical work once the 230V supply has been discon-
nected.
³
The mains must be connected as follows:
F
to a insulated distribution unit with protective contact
F
to a socket with protective contact (isolated ground or suitable plug
connector from WAGO
®
, depending on LAS 1218-2 variant).
The power cord must be of type H05VV-F 3x1.5.
³
The mains cable must have a strain relief where required.
2.4 Initial use
2.4.1 Checks prior to initial use
³
Ensure that the batteries are connected properly (only for initial use, ope-
ration without battery is possible in general).
2.4.2 Setting battery type
³
Establish battery type.
Y
DANGER!
Incorrect setting of the battery selector switch.
Risk of explosion from build-up of electrolytic gas, defective battery, defec-
tive battery charger or as a result of too high a battery operating tempera-
ture (above 30
°
C):
F
Move the battery selector switch to the correct position.
F
The battery charger is to be used solely for connecting to the 12V
power supply with rechargeable 6-cell lead-gel or lead-acid batteries.
Do not use any unsuitable battery types.
³
Store batteries in a place with adequate ventilation (or provide integrated
ventilation). Follow the instructions provided by the battery manufacturer.
lead-gel
lead-acid
Fig. 8
Battery selector switch lead-gel-/lead-acid battery.
Mains connection