![Schaudt LAS 1218-2 Manual Download Page 29](http://html.mh-extra.com/html/schaudt/las-1218-2/las-1218-2_manual_1210317029.webp)
Instruction Manual and Installation Instructions LAS 1218-2
9
Date: 06.11.2014
810.523 BA / EN
134,
2
147,
2
118,
1
80
90
163,5
247,5
Flat pins 6.3 x 0.8
in the insulation housing
4 x attachment-
holes, ø4.5
Fig. 1
Dimension diagram of LAS 1218-2 battery charger (dimensions in mm)
2.2.2 Fuse holder
For applications that require one or two additional fuses (see sections
1.1.1.2 and 1.1.1.3 for example), fuse holders from the connector set must
be installed.
³
Determine the place of installation of the fuse holder(s). The place of in-
stallation must be in the direct vicinity of the corresponding battery.
³
Drill a hole 8mm in diameter for every fuse holder.
³
Lock the fuse holder into place in the drillhole.
2.3 Electrical connection
The battery charger connection is established in the following order:
1. All connections on the front panel of the battery charger
2. Battery lines to the battery terminals
3. 230V mains connection
Disconnect in the reverse order.
2.3.1 Connections on the front panel
Y
ATTENTION!
Short circuits!
Damage to the battery charger or fire damage to cable:
F
To protect the supply lines in the event of a short circuit, connect the
fuses directly to the positive terminal of battery.
Connection sequence
Disconnecting