Connection to additional battery (such as when using in
conjunction with inverter)
With this type of connection, the LAS 1218-2 battery charger is used for loa-
ding an additional battery.
The following parts are supplied under item number 999.086 for this applica-
tion:
1
2
3
4
5
6
7
Fig. 6
Connector set deliverables
Pos.
Qty
Name
1
1
LAS 1218-2 battery charger
2
7
Flat push-on contacts, 6.3 x 0.8 (blue)
3
3*
Ring terminal, 1 ... 2.5 mm
2
M6
4
3*
Ring terminal, 1 ... 2.5 mm
2
M8
5
2*
Fuse holder for flat vehicle fuse
6
1
Flat vehicle fuse, 20A
7
1*
Flat vehicle fuse, 10 A
* Pos. 3 and 4 each only required 2 x, Pos. 5 only 1 x, Pos. 7 not used.
The connector set (Pos. 2 to 6) is required to connect the LAS 1218-2 bat-
tery charger to the additional battery.
The application shown in Fig. 7 is based on articles ”Connector sets for integra-
tion of an inverter” (article nos 798.023 and 999.208) available from Schaudt. In
principle, such a connection is always suitable when an addition battery is char-
ged.
Y
The length of the line to the additional battery may not exceed 4 m (sup-
ply and return lines together) for a cable cross-section of 2.5mm
2
(see
also table on page 9).
³
+ terminal of LAS 1218-2 (flat push-on contact 6.3 x 0.8) to F4 (flat push-
on contact 6.3 x 0.8)
Deliverables