Instruction Manual Electrobloc EBL 99 G

3

Description and appropriate use

The Electrobloc EBL 99 G is designed as a main power distributor for 
motorhomes/caravans. The Electrobloc is a permanent installation. The Elec-
trobloc is for charging batteries and supplying 12 V appliances with power.

The electrical management system Electrobloc EBL 99 G consists of:

P

The LAS 1218 charger module

P

The 12 V distribution

P

Fuses for the 12 V circuits

P

A battery monitor module

P

Other control and monitoring functions

The charger module is a primary controlled switch-mode power supply. This 
modern switching technology achieves high charging performance at a com-
pact size and low weight.

A control and switch panel has to be connected for operation. This control and 
switch panel controls the electrical functions in the living area of in the 
motorhome, including accessories.

W

Danger of burning! During operation the back of the Electrobloc gets 
hot. Do not touch.

W

Danger of explosion from formation of detonating gas due to an incor-
rectly set battery selector switch, defective batteries, defective Elec-
trobloc or an excessively high battery working temperature (more than 
30 °C).

W

The AES refrigerator fuse may only be used if a AES refrigerator is con-
nected. Otherwise, the living area battery may get totally discharged. Bat-
tery damage is possible.

W

An incorrectly set battery selector switch damages the living area battery.

W

Disconnect the Electrobloc from the mains before adjusting the battery 
selector switch.

W

If the living area battery is separated from the Electrobloc using the 12 V 
main switch at the control and switch panel, the frost protection valve of 
the heater system opens. Water may be lost. For more information, see 
the instruction manual of the heater system.

W

Before and after shutdown, the living area battery must be fully recharged 
to avoid battery damage. For this purpose the vehicle must be connected 
to mains supply for a minimum of 12 hours with an 80 Ah battery and 
24 hours with a 160 Ah battery.

W

Do not operate the Schaudt solar charge regulator without a battery. This 
might damage the solar charge regulator or any connected consumers. If 
the battery is going to be changed or removed, please first take off the pos-
itive lead "+ Solarzelle" (+ Solar Module) on the solar charge regulator.

W

To avoid voltage peaks during warm-up, do not connect the generator until 
it is running in a stable manner. Otherwise, the Electrobloc, the 12 V con-
sumers or other connected equipment might get damaged. It is essential 
that the generator complies with the mains supply specifications.

W

The mains supply on board car ferries might not always be perfect. There-
fore, never connect the Electrobloc to the mains on car ferries. Otherwise, 
the Electrobloc, the 12 V consumers or other connected equipment might 
get damaged.

Summary of Contents for 911.417

Page 1: ...struction manual Electrobloc EBL 99 G Type no 911 417 Table of contents 1 Introduction 2 2 Safety information 2 3 Description and appropriate use 3 4 Suitable accessories not supplied 4 5 Electrical data 4 6 Operation 5 7 Maintenance 7 8 Shutting down the system 7 9 Changing the battery 8 10 Technical faults possible causes and remedies 9 11 Customer service 10 12 Block diagram for specialist work...

Page 2: ...fied personnel W Failure to comply with this sign may lead to the endangerment of per sons W Failure to comply with this sign may damage the device or the connected consumers W This sign indicates recommendations or special features W The electrical system of the motorhome or the caravan has to meet current DIN VDE and ISO regulations Manipulations of the electrical system will endanger the safety...

Page 3: ... get totally discharged Bat tery damage is possible W An incorrectly set battery selector switch damages the living area battery W Disconnect the Electrobloc from the mains before adjusting the battery selector switch W If the living area battery is separated from the Electrobloc using the 12 V main switch at the control and switch panel the frost protection valve of the heater system opens Water ...

Page 4: ...s 12 Battery cut off switch 4 Suitable accessories not supplied Control and switch panel P IT 20 2 IT 20 3 IT 95 IT 901 IT 991 IT 992 IT 993 P LT 410 LT 99 LT 993 and their variants Auxiliary charging unit Schaudt battery charging unit type LAS with up to 18 A charge current Additional 2 pin charging cable lengths supplied on request Solar charge regulator Schaudt solar charge regulator type LR fo...

Page 5: ...cut off switch or after changing batteries Switch on the 12 V main switch on the control and switch panel briefly to start up the consumers Shutting down the system Set the battery cut off switch to Batterie Aus battery off W Blown fuses must only be replaced when the cause of the fault is known and eliminated W Never bridge or repair fuses W Danger of burning Blown fuses must only be changed on a...

Page 6: ...frigerator P Spare 4 For more information see the instruction manual of the control and switch panel 6 2 Additional functions Automatic switch function for AES compressor refrigerator 7KLV UHOD VXSSOLHV WKH 6 FRPSUHVVRU UHIULJHUDWRU ZLWK SRZHU IURP WKH VWDUWHU EDWWHU ZKHQ WKH YHKLFOH HQJLQH LV UXQQLQJ DQG WKH FRQQHFWLRQ LV OLYH An AES compressor refrigerator is powered by the living area battery w...

Page 7: ...rgent Never use spirit thinners or similar substances Do not allow fluid to penetrate the inside of the Electrobloc 8 Shutting down the system Disconnecting the living area battery from the 12 V power supply Disconnect the living area battery from the 12 V power supply if you are not going to use the motorhome for a lengthy period for example during the winter Switch off the 12 V main switch on th...

Page 8: ...er changing batteries Switch on the 12 V main switch on the control and switch panel briefly to start up the consumers W The living area battery can also be charged using the internal charger module an auxiliary charging unit the solar charge regulator and the alter nator when the battery cut off switch is switched off W Batteries may only be changed by qualified personnel W Follow the instruction...

Page 9: ...s not charged during 230 V operation battery voltage constantly below 13 0 V No mains voltage Switch on the automatic fuse in the vehicle Have the mains voltage checked Defective Electrobloc Call customer service Living area battery is not charged during mobile operation battery voltage below 13 0 V Defective alternator Have the alternator checked No voltage at D input Have the fuse and wiring che...

Page 10: ...gulations 12 V power supply in the living area does not work 12 V main switch for the liv ing area battery is switched off Switch on the 12 V main switch for the living area battery Battery cut off switch is switched off Switch on the battery cut off switch Defective fuse or wiring Have the fuse and wiring checked Defective Electrobloc Call customer service Fault Possible cause Remedy W If the dev...

Page 11: ...LQGLFDWRU 1HJDWLYH VHQVRU EDWW 6HQVRU EDWW 6 EDWW DWWHU FXW RII VZLWFK 2II 5HIULJHUDWRU UHOD 1RW DVVLJQHG 1RW DVVLJQHG 1RW DVVLJQHG LUFXLW ERDUG 3 D 7 SH QR 5HIULJHUDWRU UHOD 01 VRFNHW FDS EORFN 01 VRFNHW FDS EORFN HDFK PPð PD P 6HQVRU 1HJDWLYH VHQVRU URVW SURWHFWLRQ YDOYH 6 IRU UHIULJHUDWRU HDWHU LQSXW 1HJDWLYH 6 IRU UHIULJHUDWRU ORRU OLJKW VWHS 01 VRFNHW FDS EORFN RPSUHVVRU 6 UHIULJHUDWRU 01 VRF...

Page 12: ... completed fault report There is the following defect please tick Other remarks Device type Type no EBL 99 G 911 417 Battery not being charged during power operation Battery not being charged during mobile operation The following electrical con sumers do not work Malfunction of control and switch panel Tank Voltage Current Constant fault Temporary fault loose con tact ...

Reviews: