background image

8

Situation: 15.06.2005

SDT-0054-00EN

Instruction Manual Electrobloc EBL 99 G

9

Changing the battery

Only use batteries of the same type and capacity and those installed by the 
manufacturer.

You can change from lead acid to lead gel batteries.

You cannot change from lead gel to lead acid batteries. Ask your dealer for 
advice.

The switching option provided by the battery selector switch ensures optimum 
charging of the two different types of battery, lead acid and lead gel. The 
switch must be set to the correct battery type: lead acid or lead gel.

Use a thin object (e. g.  a ballpoint pen cartridge) to move the battery selector 
switch.

„

Set lead gel battery: Set the battery selector switch to "Blei-Gel" (lead gel).

„

Set lead acid battery: Set the battery selector switch to "Blei-Säure" (lead 
acid).

Starting up the system

„

Set the battery cut-off switch on the Electrobloc to "Batterie Ein" (battery 
on).

„

After switching on the battery cut-off switch or after changing batteries: 
Switch on the 12 V main switch on the control and switch panel briefly to 
start up the consumers.

W

The living area battery can also be charged using the internal charger 
module, an auxiliary charging unit, the solar charge regulator and the alter-
nator when the battery cut-off switch is switched off.

W

Batteries may only be changed by qualified personnel.

W

Follow the instructions of the battery manufacturer.

W

To disconnect the battery from the Electrobloc, all you need to do is set the 
battery cut-off switch on the Electrobloc to "Batterie Aus" (battery off).

W

Charging unsuitable types of battery may irreparably damage them.

W

Only use the Electrobloc for connecting the 12 V power supply to 6-cell 
lead gel or lead acid batteries.

W

Danger of explosion from formation of detonating gas due to an incor-
rectly set battery selector switch, defective batteries, defective Electro-
bloc or an excessively high battery working temperature (more than 
30 °C).

W

An incorrectly set battery selector switch damages the living area battery.

W

Disconnect the Electrobloc from the mains before adjusting the battery 
selector switch.

Summary of Contents for 911.417

Page 1: ...struction manual Electrobloc EBL 99 G Type no 911 417 Table of contents 1 Introduction 2 2 Safety information 2 3 Description and appropriate use 3 4 Suitable accessories not supplied 4 5 Electrical data 4 6 Operation 5 7 Maintenance 7 8 Shutting down the system 7 9 Changing the battery 8 10 Technical faults possible causes and remedies 9 11 Customer service 10 12 Block diagram for specialist work...

Page 2: ...fied personnel W Failure to comply with this sign may lead to the endangerment of per sons W Failure to comply with this sign may damage the device or the connected consumers W This sign indicates recommendations or special features W The electrical system of the motorhome or the caravan has to meet current DIN VDE and ISO regulations Manipulations of the electrical system will endanger the safety...

Page 3: ... get totally discharged Bat tery damage is possible W An incorrectly set battery selector switch damages the living area battery W Disconnect the Electrobloc from the mains before adjusting the battery selector switch W If the living area battery is separated from the Electrobloc using the 12 V main switch at the control and switch panel the frost protection valve of the heater system opens Water ...

Page 4: ...s 12 Battery cut off switch 4 Suitable accessories not supplied Control and switch panel P IT 20 2 IT 20 3 IT 95 IT 901 IT 991 IT 992 IT 993 P LT 410 LT 99 LT 993 and their variants Auxiliary charging unit Schaudt battery charging unit type LAS with up to 18 A charge current Additional 2 pin charging cable lengths supplied on request Solar charge regulator Schaudt solar charge regulator type LR fo...

Page 5: ...cut off switch or after changing batteries Switch on the 12 V main switch on the control and switch panel briefly to start up the consumers Shutting down the system Set the battery cut off switch to Batterie Aus battery off W Blown fuses must only be replaced when the cause of the fault is known and eliminated W Never bridge or repair fuses W Danger of burning Blown fuses must only be changed on a...

Page 6: ...frigerator P Spare 4 For more information see the instruction manual of the control and switch panel 6 2 Additional functions Automatic switch function for AES compressor refrigerator 7KLV UHOD VXSSOLHV WKH 6 FRPSUHVVRU UHIULJHUDWRU ZLWK SRZHU IURP WKH VWDUWHU EDWWHU ZKHQ WKH YHKLFOH HQJLQH LV UXQQLQJ DQG WKH FRQQHFWLRQ LV OLYH An AES compressor refrigerator is powered by the living area battery w...

Page 7: ...rgent Never use spirit thinners or similar substances Do not allow fluid to penetrate the inside of the Electrobloc 8 Shutting down the system Disconnecting the living area battery from the 12 V power supply Disconnect the living area battery from the 12 V power supply if you are not going to use the motorhome for a lengthy period for example during the winter Switch off the 12 V main switch on th...

Page 8: ...er changing batteries Switch on the 12 V main switch on the control and switch panel briefly to start up the consumers W The living area battery can also be charged using the internal charger module an auxiliary charging unit the solar charge regulator and the alter nator when the battery cut off switch is switched off W Batteries may only be changed by qualified personnel W Follow the instruction...

Page 9: ...s not charged during 230 V operation battery voltage constantly below 13 0 V No mains voltage Switch on the automatic fuse in the vehicle Have the mains voltage checked Defective Electrobloc Call customer service Living area battery is not charged during mobile operation battery voltage below 13 0 V Defective alternator Have the alternator checked No voltage at D input Have the fuse and wiring che...

Page 10: ...gulations 12 V power supply in the living area does not work 12 V main switch for the liv ing area battery is switched off Switch on the 12 V main switch for the living area battery Battery cut off switch is switched off Switch on the battery cut off switch Defective fuse or wiring Have the fuse and wiring checked Defective Electrobloc Call customer service Fault Possible cause Remedy W If the dev...

Page 11: ...LQGLFDWRU 1HJDWLYH VHQVRU EDWW 6HQVRU EDWW 6 EDWW DWWHU FXW RII VZLWFK 2II 5HIULJHUDWRU UHOD 1RW DVVLJQHG 1RW DVVLJQHG 1RW DVVLJQHG LUFXLW ERDUG 3 D 7 SH QR 5HIULJHUDWRU UHOD 01 VRFNHW FDS EORFN 01 VRFNHW FDS EORFN HDFK PPð PD P 6HQVRU 1HJDWLYH VHQVRU URVW SURWHFWLRQ YDOYH 6 IRU UHIULJHUDWRU HDWHU LQSXW 1HJDWLYH 6 IRU UHIULJHUDWRU ORRU OLJKW VWHS 01 VRFNHW FDS EORFN RPSUHVVRU 6 UHIULJHUDWRU 01 VRF...

Page 12: ... completed fault report There is the following defect please tick Other remarks Device type Type no EBL 99 G 911 417 Battery not being charged during power operation Battery not being charged during mobile operation The following electrical con sumers do not work Malfunction of control and switch panel Tank Voltage Current Constant fault Temporary fault loose con tact ...

Reviews: