for example from vertical to horizontal (privacy on/off). The 

motor run time for this angle adjustment can be set from 0.1 

to 1.4 s. A triple button press initiates the full motor run time 

(setting range 3 to 240 s).

If 

automatic closing

 is enabled, the drive starts moving in 

the closing direction after the set closing time delay. The 

time-out is started by the signal on the VA local input.

If the signal on the VA input is active longer than 2 seconds, 

the closing time is doubled. In louver blind mode a reverse 

pulse is configured instead of the closing function, so that 

the louvers are automatically reset after the motor stops.

Central push-button motor control mode (Z)

 enables simple 

central control in relatively small systems without a higher-

level group controller. The auxiliary inputs can be actuated by 

push-buttons in the same way as the local inputs, but they 

take priority.

Controls and indicators

Motor run time setting „Motor-Laufzeit“:

This sets the motor run time:

T   

Button mode (motor runs only when an input signal is active)

3–240  Motor run time in seconds

∞   

No run time limit

Status indicator LEDs:

 LED off

 LED lit red

 LED blinks red

 LED lit green

 LED blinks green

 LED blinks alternating red/green

Mode setting „Mode“:

This sets the operating mode:

M   

Motor control

 

 

(short button press for Open, Close or Stop)

J   

Louvre blind control

 

 

(short button press for fine adjustment of louvre angle or stop; long but

 

 

ton press for open/close)

GM  

Group device for motor control*

 

 

(no time monitoring)

GJ   

Group device for louvre blind control* 

 

 

(no time monitoring)

SJ   

Only UMS 5/U5:

 Louvre blind privacy

 

 

(short button press sets privacy on or off; triple button press to adjust 

 

 

blind position)

Z   

Central push-button motor control

 

 

(all inputs operated by push-buttons)

U4   

Only UMS 5P:

 mode for downwards compatibility to UMS 4

* In mode GM or GJ, relay output M1 or M2 (14 or 24) is continuously closed as long as an active signal 
is present on an auxiliary input. This enables override actuation (with local inputs blocked) by sensors 
(wind sensor, rain sensor, etc.).
In mode „U4“ the UMS 5P behaves as the former model UMS 4, and therfore can be used as a repla-
cement device or for extension of older equipment. In this mode, the motor only stops when button is 
pressed at VA or VZ, and doesn‘t change direction.

Automatic closing time setting „autom. Rücklauf“:

This sets the automatic closing time, reverse pulse time or louvre run time:

In motor control mode (M):

Time for automatic closing function 

3 s to 30 min

 or 

Off

 (function disabled)

In louvre blind control mode (J):

Duration of reverse pulse 

0.1 to 1.3 s

 or 

Off 

(function 

disabled)

In louvre blind privacy mode (SJ):

Louvre run time 

0.1 to 1.4 s

Summary of Contents for UMS 5

Page 1: ...lications Roller shutters and louvre blinds shutters skylights smoke extraction hoods in fire protection systems door drives valve drives etc Operation The UMS is actuated by standard push buttons wit...

Page 2: ...green Mode setting Mode This sets the operating mode M Motor control short button press for Open Close or Stop J Louvre blind control short button press for fine adjustment of louvre angle or stop lon...

Page 3: ...UMS 5 230V AC UMS U5 230V AC The UMS 5 230V AC model supports the assignment of different phases for the supply voltage the local inputs and auxiliary inputs Attention For UMS U5 supply voltage and c...

Page 4: ...istance 8mm Electrical isolation creepage clearance distance 8mm Central or group control 2 button control Open Close Universal voltage 12 230V AC DC UMS 5 24V UC The 24V UC variant UMS504 and the 12...

Page 5: ...running times the limit switches of some motors may be reached while other motors are still running The motors that are already switched off would then receive inductive voltage at the counterwinding...

Page 6: ...al control 2 button control 1 button control Further local controllers Close Open Central Close Open Group 1 Close Open Local 1 Open Close Local 2 Close Open Group 2 Close Open Local 3 Open Close Loca...

Page 7: ...p control Local control 2 button control 1 button control Open Group 1 Local 1 Local 2 Close Open Close Open Close Open Close Further local controllers Further local controllers Open Close Open Close...

Page 8: ...matic operation Central control Local control 2 button control 1 button control Further local controllers Wind monitor rain monitor or time switch Local 1 Close Open Open Close Local 2 Local 3 Close O...

Page 9: ...higher level controller This further grouping is called central control Rain wind and light The various limit switches are connected to the VA VZ or NA NZ inputs of the central controller Safety relat...

Page 10: ...ening or closing may be necessary depending on the application Light sensor SL 2 Rain sensor SR 1 Wind sensor SW 4 Close Open Central Close Open Local Close Open Local Close Open Local Observe polarit...

Page 11: ...are level controlled in respon se to short press of button and edge controlled when button held down Set louver blind counter run counter running tg is triggered by timeout of VZ or by manual stop Op...

Page 12: ...0 V 50 60 Hz 10 respectively 24 V DC AC 10 Control voltage operating voltage Only UMS 5P NA NZ inputs are 12 230V UC capable Power consumption passive 0 2W active 0 4W Run time 3 240s Automatic closin...

Reviews: