UMS 5 / UMS U5 function diagrams

All operating modes and set motor running time:

local inputs are edge-triggered and time-monitored

Motor running time in pushbutton mode: local inputs

are level-controlled and 

not

 time-monitored

Operating modes M and J with motor running time:

auxiliary inputs are level-controlled and time-monitored

Modes GM and GJ or motor running time set to „T“:

auxiliary inputs are level-controlled and not time-monitored

When a reverse pulse time is set, the reversal is started or

retriggered after releasing VA

tvu = Switchover pause (0.6s) between K14 and K24

for motor protection (mechanical stress release). As one local 

button is active, the other local button is ignored:

As one local button is active, the other local button

is ignored. NA overrides NZ:

Louver blind mode: local inputs are level-controlled in respon-

se to short press of button and edge-controlled when button 

held down

Set louver blind counter-run: counter-running (t

g

) is triggered 

by timeout of VZ or by manual stop

Operating mode Z with motor running time: auxiliary

inputs are edge-controlled and time-monitored

Mode SJ 

(does not apply UMS 5P)

:

Actuating a local input once, the motor will start turning in the selected direction with the set duration (0.1 to 1.4s). Actuating 

a local input 3 times in direct succession, the set motor run time (3 to 240s) is started. Closing run time (K24) lasts 25% 

longer than the opening run time (K14), to ensure a defined starting position for the next turn.

U4 mode (applies only to UMS 5P): When actuating VA and VZ 

alternately, the motor will not directly turn direction but stops 

the motor. The auxiliary inputs behave as in mode Z.

(Open)

Motor run time

Motor run time

Motor run time

Motor run 

time

Motor run 

time

Motor run time

Motor run time

(Open)

(Open)

(Open)

(Close)

(Open)

(Open)

K24 

(Close)

(Open)

(Open)

(Open)

(Close)

(Close)

(Open)

K24 

(Close)

Delay

(Open)

(Close)

Summary of Contents for UMS 5

Page 1: ...lications Roller shutters and louvre blinds shutters skylights smoke extraction hoods in fire protection systems door drives valve drives etc Operation The UMS is actuated by standard push buttons wit...

Page 2: ...green Mode setting Mode This sets the operating mode M Motor control short button press for Open Close or Stop J Louvre blind control short button press for fine adjustment of louvre angle or stop lon...

Page 3: ...UMS 5 230V AC UMS U5 230V AC The UMS 5 230V AC model supports the assignment of different phases for the supply voltage the local inputs and auxiliary inputs Attention For UMS U5 supply voltage and c...

Page 4: ...istance 8mm Electrical isolation creepage clearance distance 8mm Central or group control 2 button control Open Close Universal voltage 12 230V AC DC UMS 5 24V UC The 24V UC variant UMS504 and the 12...

Page 5: ...running times the limit switches of some motors may be reached while other motors are still running The motors that are already switched off would then receive inductive voltage at the counterwinding...

Page 6: ...al control 2 button control 1 button control Further local controllers Close Open Central Close Open Group 1 Close Open Local 1 Open Close Local 2 Close Open Group 2 Close Open Local 3 Open Close Loca...

Page 7: ...p control Local control 2 button control 1 button control Open Group 1 Local 1 Local 2 Close Open Close Open Close Open Close Further local controllers Further local controllers Open Close Open Close...

Page 8: ...matic operation Central control Local control 2 button control 1 button control Further local controllers Wind monitor rain monitor or time switch Local 1 Close Open Open Close Local 2 Local 3 Close O...

Page 9: ...higher level controller This further grouping is called central control Rain wind and light The various limit switches are connected to the VA VZ or NA NZ inputs of the central controller Safety relat...

Page 10: ...ening or closing may be necessary depending on the application Light sensor SL 2 Rain sensor SR 1 Wind sensor SW 4 Close Open Central Close Open Local Close Open Local Close Open Local Observe polarit...

Page 11: ...are level controlled in respon se to short press of button and edge controlled when button held down Set louver blind counter run counter running tg is triggered by timeout of VZ or by manual stop Op...

Page 12: ...0 V 50 60 Hz 10 respectively 24 V DC AC 10 Control voltage operating voltage Only UMS 5P NA NZ inputs are 12 230V UC capable Power consumption passive 0 2W active 0 4W Run time 3 240s Automatic closin...