UMS 5P (230V AC)
The UMS 5P auxiliary inputs are electrically isolated. The auxiliary inputs can thus also be controlled from different phases of
the power network. Allowed control voltage: 12V - 230V AC or DC.
The electrically isolated auxiliary inputs of the UMS 5P should not be permanently actuated when driven with
230V, since this leads to increased heating.
Info
Electrical isolation
creepage/clearance distance=8mm
Electrical isolation
creepage/clearance distance=8mm
Central or group control
2-button control
Open
Close
Universal voltage*
12-230V AC / DC
UMS 5 (24V UC):
The (24V UC variant (UMS504) and the 12-24V UC variant (UMSU5V)-need 24V respectively 12-24V UC both for supply and
control voltage. However the potential-free relay contacts can drive 230V motors.
Central or group con-
trol, wind sensor,...
1-button control
Open/Close
Electrical isolation
creepage/clearance distance=8mm
2-button control
Open
Close
1-button control
Open/Close
230V AC for motor power supply
Open
Close
UMS U5 (24V UC):
Electrical isolation
creepage/clearance distance=8mm
group control