UMS 5P (230V AC)

The UMS 5P auxiliary inputs are electrically isolated. The auxiliary inputs can thus also be controlled from different phases of 

the power network. Allowed control voltage: 12V - 230V AC or DC.

The electrically isolated auxiliary inputs of the UMS 5P should not be permanently actuated when driven with 

230V, since this leads to increased heating.

Info

Electrical isolation

creepage/clearance distance=8mm

Electrical isolation

creepage/clearance distance=8mm

Central or group control

2-button control

Open

Close

Universal voltage*

12-230V AC / DC

UMS 5 (24V UC):

The (24V UC variant (UMS504) and the 12-24V UC variant (UMSU5V)-need 24V respectively 12-24V UC both for supply and 

control voltage. However the potential-free relay contacts can drive 230V motors.

Central or group con-

trol, wind sensor,...

1-button control

Open/Close

Electrical isolation

creepage/clearance distance=8mm

2-button control

Open

Close

1-button control

Open/Close

230V AC for motor power supply

Open

Close

UMS U5 (24V UC):

Electrical isolation

creepage/clearance distance=8mm

group control

Summary of Contents for UMS 5

Page 1: ...lications Roller shutters and louvre blinds shutters skylights smoke extraction hoods in fire protection systems door drives valve drives etc Operation The UMS is actuated by standard push buttons wit...

Page 2: ...green Mode setting Mode This sets the operating mode M Motor control short button press for Open Close or Stop J Louvre blind control short button press for fine adjustment of louvre angle or stop lon...

Page 3: ...UMS 5 230V AC UMS U5 230V AC The UMS 5 230V AC model supports the assignment of different phases for the supply voltage the local inputs and auxiliary inputs Attention For UMS U5 supply voltage and c...

Page 4: ...istance 8mm Electrical isolation creepage clearance distance 8mm Central or group control 2 button control Open Close Universal voltage 12 230V AC DC UMS 5 24V UC The 24V UC variant UMS504 and the 12...

Page 5: ...running times the limit switches of some motors may be reached while other motors are still running The motors that are already switched off would then receive inductive voltage at the counterwinding...

Page 6: ...al control 2 button control 1 button control Further local controllers Close Open Central Close Open Group 1 Close Open Local 1 Open Close Local 2 Close Open Group 2 Close Open Local 3 Open Close Loca...

Page 7: ...p control Local control 2 button control 1 button control Open Group 1 Local 1 Local 2 Close Open Close Open Close Open Close Further local controllers Further local controllers Open Close Open Close...

Page 8: ...matic operation Central control Local control 2 button control 1 button control Further local controllers Wind monitor rain monitor or time switch Local 1 Close Open Open Close Local 2 Local 3 Close O...

Page 9: ...higher level controller This further grouping is called central control Rain wind and light The various limit switches are connected to the VA VZ or NA NZ inputs of the central controller Safety relat...

Page 10: ...ening or closing may be necessary depending on the application Light sensor SL 2 Rain sensor SR 1 Wind sensor SW 4 Close Open Central Close Open Local Close Open Local Close Open Local Observe polarit...

Page 11: ...are level controlled in respon se to short press of button and edge controlled when button held down Set louver blind counter run counter running tg is triggered by timeout of VZ or by manual stop Op...

Page 12: ...0 V 50 60 Hz 10 respectively 24 V DC AC 10 Control voltage operating voltage Only UMS 5P NA NZ inputs are 12 230V UC capable Power consumption passive 0 2W active 0 4W Run time 3 240s Automatic closin...

Reviews: