Advanced SkLineScan Software Functions
29
Instruction Manual
SK6288VKOC-4L
shar
ed_CameraContr
ol(5)_Advanced-Sync-Ctrl_ML.indd
Instruction Manual SK6288VKOC-4L © 2018-04 E
•
Trigger on falling edge
of SyncA
•
SyncB = low active
•
direction detection = on
•
hysteresis = 0
Sync Control Register:
'1000 0xxx'b
B
1)
•
Trigger on falling edge
of SyncA
•
SyncB without function
•
direction detection = off
•
hysteresis = 0
Sync Control Register:
'0xxx xxxx'b
A
1)
•
Trigger on falling edge
of SyncA
•
SyncB = low/high active
•
direction detection = on
•
hysteresis = 0
Sync Control Register:
'1100 0xxx'b
C
1)
•
Trigger on 4 edges
of SyncA and SyncB
•
direction detection = on
•
hysteresis = 0
Sync Control Register:
'1110 0xxx'b
D
1)
•
Trigger on 4 edges
of SyncA and SyncB
•
direction detection = on
•
hysteresis = 4
Sync Control Register:
'1110 1xxx'b
E
2)
1)
1)
1)
machine holdup oscillation
Example Timing Diagrams of Advanced Synchronization Control
Annotations:
SyncA
= LINE SYNC A (external line synchronization input, I/O connector)
SyncB
= LINE SYNC B (external line synchronization input, I/O connector)
Count
= internal counter
Trigger
= Generated trigger pulses from the Trigger Control stage. The signal goes to the Trigger
Divider stage inside the camera. For setting the divider, use the V
yyyyy
<CR> command or the
'Divider' input field in the
4.1 Camera Control by Commands (p. 20)
.
1) direction changed
2) glitch