www.schaerer.com
Troubleshooting
Operating instructions / V04/03.2012
35/42
overtemperature steam
●
The steam temperature has fallen to 115 °C.
►
Wait until the temperature has been reached
again.
► Switch the machine off and then back on.
►
Contact service partner.
Initialisation...
●
The software and the processor are restarted.
●
The brewer moves to the "Home" position.
► Switch the machine off and then back on.
►
Contact service partner.
timeout fridge
The set temperature of the cooling unit was not
reached within 4 minutes after the machine was
switched on.
► Switch the machine off and back on.
►
If the message persists: contact your service part-
ner.
no milk
● The milk container is empty.
● The milk system is clogged.
● The milk system was wrongly disabled.
► Check whether the milk container is filled.
►
Perform the daily cleaning routine.
►
If the malfunction persists: contact your service
partner.
Malfunction without display message
Fault
Cause
What to do
no milk foam
● The milk container is empty.
● The milk system is clogged.
● The milk system was wrongly disabled.
► Check whether the milk container is filled.
►
Perform the daily cleaning routine.
►
If the malfunction persists: contact your service
partner.